Debris tank, Fx50 operator’s manual – Ditch Witch FXT50 User Manual
Page 106
FX50 Operator’s Manual
Service - 105
As Needed
CMW
Debris Tank
Clean Primary Shutoff Valve
Clean primary shutoff valve as needed. Replace
primary shutoff valve as needed.
To clean:
1.
Open tank door. See “Open/Close Tank Door”
on page 66.
2.
Spray valve housing inside vacuum tank with
high-pressure water.
3.
Store water pressure hose.
4.
Close tank door. See “Open/Close Tank Door”
on page 66.
To remove:
1.
Loosen three wingnuts (1) and pull out valve housing (2).
2.
Remove ball (3).
3.
Clean ball and housing with high-pressure water.
4.
Replace ball and housing.
5.
Tighten wingnuts.
22
33
11
j36om054w.eps