FX50 Operator’s Manual

Service - 105

As Needed

CMW

Debris Tank

Clean Primary Shutoff Valve

Clean primary shutoff valve as needed. Replace
primary shutoff valve as needed.

To clean:

1.

Open tank door. See “Open/Close Tank Door”
on page 66.

2.

Spray valve housing inside vacuum tank with
high-pressure water.

3.

Store water pressure hose.

4.

Close tank door. See “Open/Close Tank Door”
on page 66.

To remove:

1.

Loosen three wingnuts (1) and pull out valve housing (2).

2.

Remove ball (3).

3.

Clean ball and housing with high-pressure water.

4.

Replace ball and housing.

5.

Tighten wingnuts.

22

33

11

j36om054w.eps