Cold start procedure, Fx50 operator’s manual – Ditch Witch FXT50 User Manual
Page 58
FX50 Operator’s Manual
Vacuum and Pothole - 57
Start Unit
CMW
Cold Start Procedure
1.
Open tank inlet valve.
2.
If equipped with reverse flow, ensure vacuum is in “vacuum” mode before starting.
3.
Insert key.
4.
Turn key clockwise to “run” position (key on, engine off). See page 24 for more information. Cold start
wait indicator will light.
5.
Wait for cold start wait indicator to go off.
6.
Turn key all the way clockwise to start engine.
7.
Run engine at low throttle for 5 minutes.
Explosion possible. Serious injury or equipment damage could occur.
Follow directions carefully.
To help avoid injury: do not use ether or starting fluid.
NOTICE: Avoid idling engine with inlet valve closed.
NOTICE: If engine turns but does not start within 10 seconds, allow starter to cool before trying to
start engine again.