beautypg.com

Fx50 operator’s manual – Ditch Witch FXT50 User Manual

Page 86

background image

FX50 Operator’s Manual

Service - 85

10 Hour

CMW

Check Blower Oil Level

With frame level, check blower oil at sight glass
(2) every 10 hours. Add SGL at breather (1) as
necessary to maintain oil level at halfway point on
sight glass (2). Do not overfill.

Check Blower

Check blower every 10 hours for unusual noise or
vibration. If malfunction is detected:

1.

Stop engine.

2.

Consult blower repair manual.

Check Water Pump Oil Level

With frame level, check water pump oil at dipstick
every 10 hours. Oil should be [where?] on sight
glass (2). Add NDO at fill (1) as necessary to keep
oil at full mark on dipstick.

j36om011w.eps

1

2

j36om024w.eps

1

2

j36om013w.eps

This manual is related to the following products: