beautypg.com

Fx50 operator’s manual – Ditch Witch FXT50 User Manual

Page 105

background image

Service - 104

FX50 Operator’s Manual

As Needed

CMW

Lube Blower for Long-term Storage

Lubricate blower before long-term storage to help
prevent rust and lockup.

1.

Remove plug from fitting at filter.

2.

Start engine.

3.

Spray light oil into port and run unit for 1-2
minutes.

4.

Turn off engine.

Change Blower Relief Air Filter

Check air filter whenever vacuum gauge goes
over 16” (406 mm) of mercury. Change as
needed.

1.

Remove clamp.

2.

Remove filter and discard.

3.

Install new filter.

4.

Replace clamp.

Empty Cyclonic Separator Canister

Empty cyclonic separator canister as needed.
Open door and dump tank. Clean out cyclone
through upper access door as needed.

NOTICE: Operating system above 16” (406
mm) of mercury may result in blower damage.

IMPORTANT: Depressurize tank before
emptying cyclonic canister, cleaning filter,
clearing hoses or opening any doors.

j36om072w.eps

j36om069w.eps

11

22

j36om053w.eps

This manual is related to the following products: