Fx50 operator’s manual – Ditch Witch FXT50 User Manual
Page 105
Service - 104
FX50 Operator’s Manual
As Needed
CMW
Lube Blower for Long-term Storage
Lubricate blower before long-term storage to help
prevent rust and lockup.
1.
Remove plug from fitting at filter.
2.
Start engine.
3.
Spray light oil into port and run unit for 1-2
minutes.
4.
Turn off engine.
Change Blower Relief Air Filter
Check air filter whenever vacuum gauge goes
over 16” (406 mm) of mercury. Change as
needed.
1.
Remove clamp.
2.
Remove filter and discard.
3.
Install new filter.
4.
Replace clamp.
Empty Cyclonic Separator Canister
Empty cyclonic separator canister as needed.
Open door and dump tank. Clean out cyclone
through upper access door as needed.
NOTICE: Operating system above 16” (406
mm) of mercury may result in blower damage.
IMPORTANT: Depressurize tank before
emptying cyclonic canister, cleaning filter,
clearing hoses or opening any doors.
j36om072w.eps
j36om069w.eps
11
22
j36om053w.eps