beautypg.com

1200 tank, Fx50 operator’s manual – Ditch Witch FXT50 User Manual

Page 68

background image

FX50 Operator’s Manual

Vacuum and Pothole - 67

Open/Close Tank Door

CMW

1200 Tank:

Open

1.

Push door seal control to SEAL.

2.

Turn tank door lock counterclockwise.

3.

Pull door seal control to RELEASE.

4.

Turn door handle to DISENGAGE and pull out.

5.

Push door lift control to OPEN.

6.

Ensure door lift latch (1) engages properly.
Door lift latch (1) should be fully seated on pin
(2).

Close

1.

Fully open door to disengage door lift latch (1)
from pin (2). Latch cover (3) must be down for
tank door to close.

2.

Pull door lift control to CLOSE.

3.

Turn door handle to DISENGAGE, push in and
turn to ENGAGE.

4.

Push door seal control to SEAL.

5.

Turn tank door lock clockwise until it stops to
lock.

6.

Pull door seal control to RELEASE.

NOTICE: If door latch is not fully seated on
pin, door will close and possibly injure
someone.

om0663h.eps

1

2

om0664h.eps

1

2

3

This manual is related to the following products: