Store configuration – Cino FA470 User Manual
Page 35

Command Descriptions
2-20
Store Configuration
(ALL)
Descriptions
Save current settings into flash memory permanently
Note that this command is not available for storing the following settings: the beep sequence set by
Beeping command; trigger status set by Serial Trigger command and LED status set by Indicator
command.
Packet Format
Prefix
Opcode
Status
Length
Parameter(s)
LRC
Suffix
7Eh
80h 03h 00h
00h
00h 00h
83h
7Eh
1 Byte
3 Bytes
1 Byte
2 Bytes
0 Byte
1 Byte
1 Byte
. Host Requirements
If the device successfully received the above command issued by the host, a “Device ACK” will be sent
to the host right after the device performed the action. Otherwise, a “Device NAK” will be sent to host to
issue a command error. However, if the host can not receive any response from the device within the
user preset time-out duration, please resend the above command.
. Parameter(s) Field
Store Configuration command takes no parameters, so the Parameter(s) field is null.
. Length
Total size (bytes) of the Parameter(s) field
. LRC