Cino FA470 User Manual
Page 117

Command Descriptions
2-102
Parameter(s)
< Table 6-1-1 > Set TS Operation Parameter(s) Field (To be continued)
Parameter / PID / Size
Options
Descriptions
Presentation Control
PID : 00h 01h
Size : 00h 01h (1 Byte)
- 01h
- 02h
- 08h
Force mode
Presentation mode *
Flash mode
(See Notes)
Presentation Auto-sense
PID : 00h 02h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
Presentation Sensitivity
PID : 00h 03h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
- 05h
- 06h
Level 1
Level 2
Level 3
Level 4
Level 5 *
Level 6
Level 7
Reread Delay
PID : 00h 04h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
- 05h
Disable
Immediate time-out duration *
Short time-out duration
Medium time-out duration
Long time out-duration
Force Verification
Flash Duty Cycle
PID : 00h 05h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
1/2 duty cycle *
(See Notes)
2/3 duty cycle
3/4 duty cycle
4/5 duty cycle
Good Read Delay
PID : 00h 06h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
- 05h
- 06h
None*
200 ms
500 ms
1 s
1.5 s
2 s
3 s
Light Source On Time
PID : 00h 07h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
Short (about 2 s) *
Medium (about 3~4 s)
Long (about 5~6 s)
Extremely Long (about 7~8 s)
Hands Free Time-out
PID : 00h 08h
Size : 00h 01h (1 Byte)
- 00h
- 06h
- 0Ah
- 0Eh
- 12h
Disable
Short *
Medium
Long
Extremely long
Time Delay To Low Power Mode
PID : 00h 09h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
- 05h
1 s
3 s
5 s
7 s
9 s
0 s (Immediately)*
.
Notes
Flash mode is not available for A Series.