Intellisense, Manual – Bimba IntelliSens User Manual
Page 41

IntelliSense
®
Manual
41
Alert Data – The following will output the state of the alarm at the time of the measurement. A value of 1
indicates that the alert was active, and 0 indicates that the alert was off.
Line Pressure High
Line Pressure Low
Sensor 1 Press High
Sensor 2 Press High
Sensor 1 Press Low
Sensor 2 Press low
Sensor 1 Temp High
Sensor 1 Temp Low
Sensor 2 Temp High
Sensor 2 Temp Low
Extend Time Low
Extend Time High
Retract Time Low
Retract Time High
Rear Seal Failure
Front Seal Failure
Rod Seal Failure
To export the logged data:
1. Select the Pressure and Date Export option button
Figure 48: Export option
2. The field selector will appear. On the right is a list of all of the available pieces of data. On the left is a grey
area where the desired fields can be dragged.
Figure 49: Export field selector
3. By default, the export file will contain the measurement time and the two pressure measurements, P1
and P2. To add any of the available fields/columns to the exported file, press the left button over the re-
quired field and drag it to the space to the left. The “Select All” command moves all of the column names
to the left column, adding them to the export report, and the “Clear” command clears any selected
column names.
Figure 50: Select variable to export
4. Items in the list can be rearranged to represent the column order in the exported file from left to right.