Intellisense, Manual – Bimba IntelliSens User Manual
Page 10

IntelliSense
®
Manual
10
Functionality
• Cylinder condition monitoring based on status LEDs on SIM unit
• By configuring a MODBUS RTU network between the users’ PLC/HMI (Master Device) and the SIM unit(s)
(Slave Device), the user can retrieve desired status values and alerts
• Data Gateway remains connected for data logging
• User PC connects to Data Gateway for initial configuration and/or real time monitoring of the SIM unit and
attached pressure system
• Use of EOT outputs with PLC installation and use of power option b)
List of Components
Required Bimba Products
• IntelliSense
®
Basic Kit- [ISK-BMAx]
o 1 - IntelliSense
®
Sensor Interface Module (SIM) [ISM-S1-BA1-5P]
o 2 - IntelliSense
®
pressure / temperature sensor [ISS-1A-7SS]
o 2 - IntelliSense
®
Tee fittings [ISF-T1-xxx]
• 2 - IntelliSense
®
sensor cable [CBL-IS-M8-x]
• 1 - IntelliSense
®
USB programming cable [CBL-IS-RU-1.8]
Optional Bimba Products
• 1 - 24 VDC Power supply [PWR-024A24-DIN] (if not supplied by user)
• 1 - IntelliSense
®
0.5 meter IO cable [CBL-IS-CF-0.5] (for EOT or power option a)
• 1 – IntelliSense
®
Junction Block [ISH-R04] (for connection to MODBUS network and power option b)
User Supplied
• 12-24 VDC power source (if not using Bimba option)
• PLC with MODBUS RTU network compatibility
• Interface cable to connect RS-485 to PLC
• Computer for setup of IntelliSense
®
SIM
• PLC that will accepts a NPN (sinking) sensor (for use of EOT inputs)