Intellisense, Manual – Bimba IntelliSens User Manual
Page 37
![background image](/manuals/734386/37/background.png)
IntelliSense
®
Manual
37
Operating Condition
Extend Time:
Current measured time for the cylinder to extend
Retract Time:
Current measured time for the cylinder to retract
Sensor 1 Temp:
Current measured temperature of sensor 1
Sensor 2 Temp:
Current measured temperature of sensor 2
Line Pressure:
Current high line pressure detected by the cylinder
Sensor 1
Pressure:
Current measured pressure of sensor 1
Sensor 2
Pressure:
Current measured pressure of sensor 2
Ambient
Pressure:
Current measured atmospheric pressure
Seal Condition
Rod Seal:
Rear Piston Seal:
Front Piston Seal:
Status of each seal
Mode
Shows which mode the SIM is in:
Cylinder or Pressure/Temperature Monitoring Mode
Life Remaining
Estimated Days Remaining
Estimated cycles remaining divide by average daily
cycles
Estimated Life Remaining
Estimated cycles remaining divide by total number of
cycles
Estimated Cycles Remaining
Cycle count mode: Cycle count limit - current cycle
count
Predictive mode: Estimated number cycles at time of
prediction*
*Impredictive mode: values only update when an event
occurs
Cycle Time
Gives the stroke, dwell and total cycle time for extend
and retract
Sensor / SIM Condition
Connection status to the SIM and sensors