6 system management > power up, 7 system management > lvds backlight, 8 system management > smart fan – ADLINK Express-HL2 User Manual
Page 51

Express-HL2
Page 51
7.2.4.6
System Management > Power Up
Feature
Options
Description
Power Up
Info only
Power Up watchdog
Attention: F12 disables the Power Up
Watchdog
.
Enabled
Disabled
The Power-Up Watchdog resets the system after a certain
amount of time after power-up
.
ECO
Mode
Disabled
Enable
Reduces the power consumption of the system
.
Power-up
Mode
Attention: The Power-Up Mode only has effect,
if the module is in ATX-Mode
.
Turn on
Remain off
Last State
Turn On: The machine starts automatically when the power
supply is turned on
.
Remain Off :To start the machine the power button has to be
pressed
.
Last State: when powered on during a power failure the system
will automatically power on when power is restored
7.2.4.7
System Management > LVDS Backlight
Feature
Options
Description
LVDS Backlight
Info only
LVDS Backlight Bright
255
The value range starts by 0 and ends by 255
.
7.2.4.8
System Management > Smart Fan
Feature
Options
Description
Smart Fan
Info only
CPU Smart FanTemperature Source
CPU Sensor
System Sensor
Select CPU smart fan source
.
CPU Fan Mode
AUTO (Smart Fan)
Fan Off
Fan On
Select CPU Fan Mode
.
CPU Trigger Point 1
Read only
Trigger Temperature
15
Specifies the temperature threshold at which the BMC turns on
CPU fan with specific PWM level
.
PWM Level
30
Select PWM level
.
CPU Trigger Point 2
Read only
Trigger Temperature
60
Specifies the temperature threshold at which the BMC turns on
CPU fan with specific PWM level
.
PWM Level
40
Select PWM level
.
CPU Trigger Point 3
Read only
Trigger Temperature
70
Specifies the temperature threshold at which the BMC turns on
CPU fan with specific PWM level
.
PWM Level
63
Select PWM level
.
CPU Trigger Point 4
Read only
Trigger Temperature
80
Specifies the temperature threshold at which the BMC turns on
CPU fan with specific PWM level
.
PWM Level
100
Select PWM level
.