3 converted data representation – ADLINK ACL-6128A User Manual

Page 29

background image

Low-Level Programming

21

3.3 Converted Data Representation

Two analog output range alternatives are provided by the ACL-6128A: Unipolar
and Bipolar. The numbering of the converted data with have different
presentations for different output ranges.

3.3.1 Unipolar

Numbering

0

4095

2048

0000 0000 0000

1000 0000 0000

1111 1111 1111

V.OUT=-Vref*(0/4095)

V.OUT=-Vref*(2048/4095)

V.OUT=-Vref*(4095/4095)

Example:

Converted

Data

=2047

Binary Code

=0111 1111 1111

Vref

=-5V

V.OUT

=-(-5 V) * ( 2047/4095) = 2.499 V

3.3.2 Bipolar

Numbering

-2048

2047

0

1000 0000 0000

1111 1111 1111

V.OUT=-Vref*(-2048/2047)

V.OUT=-Vref*(0/2047)
= 0V

V.OUT=-Vref*(2047/2047)

0000 0000 0000

Example:

Converted

Data

=500

Binary Code

=1001 1111 0100

Vref

=-5V

V.OUT

=-(-5 V) * ( 500/2047) = 1.221 V