14

Installation

ACL-6128 settings (Note: this table is for the older ACL-6128 ONLY. The
ACL-6128 PCB has misprints. Please refer to the chart below for correct
jumper placement.)

Jumper

Output Range

JP3 for CH1
JP7 for CH2

JP1 & JP5 for CH1
JP2 & JP9 for CH2

0 to +5V

Unipolar
(Default)

JP3/JP7

-10

-5

JP1/JP2 JP5/JP9

UP

BP

UP

BP

0V to +10V

Unipolar

JP3/JP7

-10

-5

JP1/JP2 JP5/JP9

UP

BP

UP

BP

-5V to +5V

Bipolar

JP3/JP7

-10

-5

JP1/JP2 JP5/JP9

UP

BP

UP

BP

-10V to +10V

Bipolar

JP3/JP7

-10

-5

JP1/JP2 JP5/JP9

UP

BP

UP

BP

Figure 2.6 Output Range Summary