beautypg.com

ADLINK ACL-6128A User Manual

Page 17

background image

Installation

9

(*) : default setting ON : 0

X : don't care OFF : 1

Note : A3-A9 correspond to PC bus address lines.

How to Define a Base Address for the ACL-6128A ?

DIP1 to DIP7 in switch SW1 are one-to-one corresponding to the PC bus
address lines A9 through A3. A0, A1, and A2 are always 0. To change
the base address, change the values of A9 to A3 (shadow area of below
diagram). The following table shows how to define the base address as
Hex 2C0.

Base Address : Hex 2C0

2

C

0

1

0

1

1

0

0

0

0

0

0

A9

A8

A7

A6

A5

A4

A3

A2

A1

A0