beautypg.com

Datavideo MP6000MD User Manual

Page 40

background image

39 

Dip Switch 1 switches the MP­6000MD between simple GPI control and RS 232 control. If Dip Switch 1 is 

Off (up) the MP­6000MD responds to GPI, if it is On (down) then it responds to RS 232. The Front Panel 

and the GPI interface will be deactivated if RS 232 control is selected. (Only the “EJECT” button will work.) 

Dip Switches 

GPI Port 

DIP switch 

DIP switch 1 OFF (up), 
• GPI trigger is enabled. 

DIP switch 1 ON (When this function is turned on, the front 
panel  and  GPI  function  will  be  disabled.  Only  “EJECT” 
will work.)
 
•External RS 232 device control enabled. 

DIP switch 2 OFF (up) 
•GPI function is set to momentary closure (Pulse Trigger). 

DIP switch 2 ON 
•GPI function is set to maintained closure (Level Trigger). 

Note: Please make sure the MP 6000 is turned off before 
changing DIP switch settings.
 

The 3.5mm Stereo Jack Plug should be wired for contact closure between the inner pin and outer pin. The 

middle of the three contacts supplies a voltage which can be used to light an LED as an indication that the 

MP­6000MD is recording.