Print approval, Material, Quantities – Flex FLC Coping User Manual
Page 27: Flexcap flc quicklock radius coping
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/717758/27/background.png)
FLEXCAP FLC QUICKLOCK RADIUS COPING
FLAT VERSION
IMPORTANT!!!
MUST INDICATE PROPER RADIUS CONDITION BY
CIRCLING APPROPRIATE OUTSIDE FACE
PROVIDING A RADIUS
THE RADIUS MAY BE PROVIDED
IN ONE OF TWO METHODS:
1.) THE ACTUAL KNOWN RADIUS IS
OUTSIDE
FACE
ROOF LINE
OR
2.) FIELD CONDITION MEASUREMENTS
NOTE: REFER TO ATTACHED WORKSHEET
RADIUS
(PROVIDED BY APPROVER
PER DETAIL A)
TOP
VIEW
SEALANT
MIDPOINT OF
STRAIGHT EDGE
INSIDE
FACE
MIN. 2 1/4" (57 mm)
MAX. 6" (152 mm)
(914 mm)
LENGTH OF
STRAIGHT EDGE
NOTE: CHECK MEASUREMENTS ALONG ENTIRE RADIUS.
DETAIL A
MIN. 3" (76 mm)
MAX. 6" (152 mm)
%''(10mm) SPACE
PROVIDED FOR
WALL VARIATION
MOTF^* ”
splice plates are provided with factory
■ applied dual non-curing sealant strips.
“ Fabrication of radius is furnished utilizing a non-penetrating
quicklock joint, then factory sealed watertight.
Fabrication will proceed only after receipt of
signed print approval.
Print Approval:
Architect and/or contractor shall verify all
dimensions, sizes and quantities. All
products to be installed in strict accordance
with Flex's printed instructions.
Approved by:
_____________________________
MATERIAL:
___ 24 Ga. (.65 mm) Steel
___ .040" (1.01 mm) Aluminum
___ .050" (1.27 mm) Aluminum
___ .063" (1.60 mm) Aiuminum
___ Other__________________
Color: __________________________
Finish:
QUANTITIES:
Date:
.Lineal Feet 4'-0" (1.22 m) Lengths
PROJECT:
ARCHITECT:
ROOFING CONTRACTOR:
REPRESENTATIVE/DISTRIBUTOR:
Customer Service:
Phone: 800^969-0108
Fax:610-916-9501
DATE: 12/13/10
DRN BY: JJC
CKD BY: SAK
SHT# OF
DWG# 28011-11386
B
p: 800-969-0108
f; 610-916-9501
print approval