Carrier – Carrier 26H User Manual
Page 56
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/717681/56/background.png)
26H
S E R V I C E
Carrier
OBSERVATION
POSSIBLE CAUSE
REMEDY AND REFERENCE
SECTIONS
8. Long Freezing Cycle
(30 - 40 min. normal)
Siphon standpipe is poorly
seated, allowing cold water
to escape
Check water pan standpipe for
proper seating
Installation
16
Float valve leaking making
siphon during freezing
period.
Check water pressure. If over 60
psig use a pressure reducing
valve and replace if necessary
Installation
12 & 16
9. Long Defrost Cycle
(Normal 5 to 8 Minutes)
Main control set incorrectly
("cut-in"temperature too
high)
Lower "cut-in"setting
28
Low-refrigerant charge
Check charge and correct if
necessary
4
Low head pressure during
the freezing cycle
Should be 125 psi. Adjust
water regulating valve
5 & 13
Bulged freezing columns
Replace evaporator,' check main
control
10
Solenoid valve stuck shut
or only partly open (listen
for hissing)
Check solenoid and wiring
32
Leaky water regulating
valve
Check and replace i f necessary
13
Water condenser scaled up
Clean condenser with inhibited
acid
9
10. During harvest cycle unit
switches back to freezing
then again to defrost
Defective interlock in main
control
Replace
28
Cut-in Bulb loose on suet,
line
Tighten clamps
28
11. Continuous running - no
ice formed.
No make up water reaching
water pan
*
Check for stuck float valve or
plugged nozzle
11
Loss of refrigerant
Check refrigerant charge; elim
inate any leaks, add refrigerant
4
Moisture in system
Change dryer
8
Solenoid valve stuck open
Check for grounded solenoid.
Replace if necessary
32
Float setting too high
causing standpipe to
siphon
Reset float valve. Seat water pan
standpipe
Installation
16
Service 11
i
t
26H-57PD