beautypg.com

Cisco 3560 User Manual

Page 90

background image

A-6

Catalyst 3560 Switch Hardware Installation Guide

OL-6337-07

Appendix A Technical Specifications

DC input voltages for
RPS 2300 and 675

+12 V

@14 A and –48 V

@7.8 A

Power consumption

560 W

Power dissipation

220 W, 690 BTUs per hour

Power rating

0.56 kVA

Power over Ethernet

Range from 4 to 15.4 W per port, up to 370 W switch maximum

Physical Dimensions

Weight

11.3 lb (5.1 kg)

Dimensions (H x W x D) 1.73 x 17.5 x 11.8 in. (4.4 x 44.5 x 30.1 cm)

Table A-12

Specifications for the Catalyst 3560V2-48TS and 3560V2-24TS Switch

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

–13 to 158°F (–25 to 70°C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Power Requirements

AC input voltage

100 to 240 VAC (autoranging)

0.8 to 1.5 A, 50 to 60 Hz

DC input voltages for
RPS 2300 and 675

+12 V

@17 A

Power consumption

180 W, 615 BTUs per hour

Power rating

0.180 kVA

Physical Dimensions

Weight

8.5 lb (3.9 kg)

Dimensions (H x W x D) 1.73 x 11.81 x 17.5 in. (4.4 x 30 x 44.45 cm)

Table A-13

Specifications for the Catalyst 3560V2-24TS-SD Switch

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

Storage temperature

–13 to 158°F (–25 to 70°C)

Relative humidity

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4573 m)

Table A-11

Specifications for the Catalyst 3560V2-48PS and 3560V2-24PS Switch (continued)

Environmental Ranges