Commands 5-19, Esc c 3 n – Triner Scale TMU-295 User Manual
Page 59

Commands 5-19
dx = [dxL + dxH
✕
256]
dy = [dyL + dyH
✕
256]
The printable area is set as shown in the figure below.
[Notes]
• The maximum printable area in the horizontal direction (x
direction) is 210 dots.
• The maximum printable area in the vertical direction (y direction)
is 480 dots.
• If the setting values exceed the printing area, it set to the
maximum printing area automatically, depending on the values
from xL to dyH.
• If (horizontal print starting position + horizontal length) or
(vertical print starting position + vertical length) is outside the
printable area, the maximum printing area is set to the printable
area.
• When the print data is buffered in the specified printing area, the
length of the printing area in both the horizontal and vertical
direction should be 8 dots or more.
• The printing area should accommodate to the size of the print
sheet.
• When the starting point (x0, y0) exceeds the printing area, this
command is ignored.
• In standard mode, only setting of this command is effective.
[Default]
xL = xH = yL = yH = 0
dxL = 210, dxH = 0, dyL = 224, dyH = 1
[Reference]
CAN
, ESC L, ESC T
ESC c 3 n
[Name]
Select paper sensor(s) to output paper end signals
[Format]
ASCII
ESC
c
3
n
(0, 0)
Printable area of the paper
(x0, y0)
dx
dy
Printing area
(x0+dx-1,
y0+dy-1)
(209 dots, 479
dots)