beautypg.com

Commands 5-19, Esc c 3 n – Triner Scale TMU-295 User Manual

Page 59

background image

Commands 5-19

dx = [dxL + dxH

256]

dy = [dyL + dyH

256]

The printable area is set as shown in the figure below.

[Notes]

• The maximum printable area in the horizontal direction (x

direction) is 210 dots.

• The maximum printable area in the vertical direction (y direction)

is 480 dots.

• If the setting values exceed the printing area, it set to the

maximum printing area automatically, depending on the values
from xL to dyH.

• If (horizontal print starting position + horizontal length) or

(vertical print starting position + vertical length) is outside the
printable area, the maximum printing area is set to the printable
area.

• When the print data is buffered in the specified printing area, the

length of the printing area in both the horizontal and vertical
direction should be 8 dots or more.

• The printing area should accommodate to the size of the print

sheet.

• When the starting point (x0, y0) exceeds the printing area, this

command is ignored.

• In standard mode, only setting of this command is effective.

[Default]

xL = xH = yL = yH = 0
dxL = 210, dxH = 0, dyL = 224, dyH = 1

[Reference]

CAN

, ESC L, ESC T

ESC c 3 n

[Name]

Select paper sensor(s) to output paper end signals

[Format]

ASCII

ESC

c

3

n

(0, 0)

Printable area of the paper

(x0, y0)

dx

dy

Printing area

(x0+dx-1,
y0+dy-1)

(209 dots, 479
dots)