Triner Scale TMU-295 User Manual
Page 55

Commands 5-15
[Notes]
• Up to 32 tab positions (k = 32) can be set. Data exceeding 32 tab
positions is processed as normal data.
• When [n]k is less than or equal to the preceding value [n]k-1, tab
setting is finished and the following data is processed as normal
data.
• When [n]k exceeds the number of characters printable on one line,
the tab position set is equal to the maximum printable column
plus 1.
• The previously specified horizontal tab positions do not change,
even if the character width changes.
• The right-side spacing is set independently in standard and page
modes. The horizontal tab setting is set by using amount of the
right-side spacing of the mode used.
[Default]
The default tab positions are at intervals of 8 characters (columns 9,
17, 25,...) for the default character font.
ESC F n
[Name]
Set/cancel cut sheet reverse eject
[Format]
ASCII
ESC
F
n
Hex
1B
46
n
Decimal
27
70
n
[Range]
0
≤
n
≤
255
[Description] Sets or cancels the cut sheet reverse eject specified by FF.
• When the LSB of n is 0, reverse eject is canceled and forwqrd eject
is set.
• When the LSB of n is 1, reverse eject is set.
[Note]
When n cancels reverse eject, this command sets forward ejection
automatically.
[Default]
n = 0
[Reference]
FF
ESC J n
[Name]
Print and feed paper
[Format]
ASCII
ESC J
n
Hex
1B
4A
n
Decimal
27
74
n
[Range]
0
≤
n
≤
255
[Description] Prints the data in the print buffer and feeds the paper by n/60
inches.
[Note]
Sets the print position to the beginning of the line.
ESC K n
[Name]
print and revers feed