T== 1, Chapter 4 - system setup, Tank content – TeeJet 844-AB Sprayer Control User Manual

Page 8: Units of measurement

background image

6

www.teejet.com

844-AB

Memory option

This feature enables the user counters.
Select NO to disable this feature or YES to enable it.
Figure 14: Memory option

1

2 3

4 5

6 7

8 9

10 11

12

No

mem

Tank content

This feature enables a tank content counter. This counter should be

set after filling the tank and will count down according to the sprayed

volume. A zero value will disable this feature.
Figure 15: Tank content

1

2 3

4 5

6 7

8 9

10 11

12

T==

1

0

CHAPTER 4 - SYSTEM SETUP

System setup mode contains the options that customize the

controller to the sprayer or sprayer components. These include

calibration steps and parameters that will rarely change once

programmed.
Table 1: System setup mode sequence

Units of measurement
Sensor selection
Flow meter impulses
Pressure transducer low pressure calibration (P Ref)
Pressure transducer maximum rating (P HI)

Speed sensor calibration*

Proximity/magnetic impulses
Radar speed impulses

Simulated ground speed

Reference flow rate per

section

Select section
Reference pressure
Reference flow
Repeat for section 2 to 12

Regulating valve response time
Pressure regulating mode
Minimum pressure setting
Density (Liquid specific gravity)
Communications
Faces per section setting, Section 1 (HC Mode only)**
Faces per section setting, Section 2 (HC Mode only)**
Faces per section setting, Section 3 (HC Mode only)**
Faces per section setting, Section 4 (HC Mode only)**
Faces per section setting, Section 5 (HC Mode only)**
Faces per section setting, Section 6 (HC Mode only)**
Faces per section setting, Section 7 (HC Mode only)**

* During speed calibration, the 844-AB will automatically sense whether a Wheel

speed or Radar speed sensor is being used.

** The number of sections available is determined within the OEM setup options.

To enter System setup mode, press and hold the Plus and Minus

keys simultaneously. While holding the Plus and Minus keys,

also press the Programme key twice (within 3 seconds) and then

release all keys to enter System setup mode.
Press and hold the Programme key for three seconds to exit

System setup mode. Changes will be saved to the console’s

memory.
NOTE: The 844-AB console will not automatically power down

during System setup mode. The system must be exited by

holding the Programme key for three seconds. A loss of

power to the controller during System setup mode will erase

all changes not previously saved to system memory.

Units of measurement

The 844-AB is capable of working in either US or SI (Standard

international metric). Use the Plus and Minus keys to switch

units. Press the Programme key to accept the value and advance

to the next programme step.
Figure 16: Units of measurement selection

US

1

2 3

4 5

6 7

8 9

10 11

12

Table 2: Units of measurement

US

SI

Speed

MPH (miles per hour)

Km/h (kilometres per hour)

Flow

GPM (gallons per minute)

L/min (litres per minute)

Area

Acres

Ha (hectares)

Pressure

PSI (pounds per square inch) Bar

Volume

Gal (gallon)

L (litre)

Speed impulses

impulses/300ft

(impulses per 300 feet)

impulses/100m

(impluses per 100 metres)

Tree spacing

Inch

cm (centimetre)

Dose rate

GPA (gallons per acre)

L/Ha (litres per hectare)