Liquid density, Adjust pressure, Adjust speed – TeeJet 844-AB Sprayer Control User Manual

Page 18

background image

16

www.teejet.com

844-AB

Adjust pressure

If an approximate operating pressure is known, use the Plus or

Minus keys to adjust the value. The 844-AB will determine what

operating speed is required to achieve the target application rate

at the entered pressure. If the speed is too high, a set of smaller

nozzles is necessary. If the speed is too low, a set of larger nozzles

is necessary.
Figure 55: Adjust pressure

1

2 3

4 5

6 7

8 9

10 11

12

2.8

Bar

6.8

70.0

L/Ha

Km/H

Adjust speed

If an adjustment to the speed setting is required, press the

Programme key once. The speed units will flash. Use the Plus

or Minus keys to adjust the speed to the desired value. The 844-

AB will calculate the required pressure to maintain target application

rate at the entered speed. If the pressure is too high, a set of larger

nozzles is necessary or the speed must decrease. If the pressure

is too low, a set of smaller nozzles is necessary or the speed must

increase.
Figure 56: Adjust speed

1

2 3

4 5

6 7

8 9

10 11

12

5.2

Bar

10.0

70.0

L/Ha

Km/H

Liquid density

To activate the Liquid density setting, press the Auto/man key.

The D symbol will be displayed at the top of the screen. The Liquid

Density that is programmed into the console will also be displayed.

To change density, press the Plus or Minus keys. Press the

Programme key to accept the changes and return to the current

application setup step. The calculations will use the Specific gravity

(Density).
To revert back to the calculation based on spraying water, press the

Auto/man key.
Figure 57: Liquid density

1.28

1

2 3

4 5

6 7

8 9

10 11

12

NOTE: If a liquid with a density other than water will be sprayed,

and that density was programmed into the Specific gravity

(Density) step during System setup mode, the “D” symbol

must be selected during Application setup mode to activate

the alternate density.

Press the Auto/man key during Application setup mode to

activate the alternate density. A “D” will be displayed at the

top of the console to indicate the alternate density is active.

This must be displayed so that all calculations will use the

alternate density during operations. If the “D” is not at the top

of the display, calculations will be based on water (1.00).

Figure 58: Liquid density

1

2 3

4 5

6 7

8 9

10 11

12

70.0

5.7

10.0

Bar

Km/H

L/Ha

After performing the calculations, advance to the beginning of

Application Setup mode to make changes by pressing the

Programme key. If no changes are necessary then Application

setup mode is complete. Press and hold the Programme key for

three seconds. Changes to Application setup mode will be stored in

the console’s memory.
NOTE: The 844-AB console will not automatically power down

during Application setup mode. The system must be exited

by holding the Programme key for three seconds. A loss

of power to the controller during Application setup mode will

erase all changes not saved to system memory.