Min uolt, Stp bnd, Rot spd sec – TeeJet 844-AB Sprayer Control User Manual
Page 7: Dsp stbl, 2 xi6h, Minimum voltage, Deadband, Rotation speed, Display stable, Total area
![background image](/manuals/713579/7/background.png)
5
98-70007-EN R4
844-AB
Minimum voltage
This will determine the minimum voltage that can be applied to the
regulation valve. If too low, the valve won’t fine tune the dose rate. If
too high, the valve could have some unstable regulation.
Figure 8: Minimum voltage
1
2 3
4 5
6 7
8 9
10 11
12
3.5
Min
UOlt
Deadband
This will determine the regulation dead band. This setting will avoid
continuous regulation when the dose rate is very close to the target
doise rate. If too low, the valve could have some unstable regulation.
If too high, the real dose rate could be far away from the target.
Figure 9: Deadband
1
2 3
4 5
6 7
8 9
10 11
12
1.5
STp
bnd
Rotation speed
This will determine the time needed by the regulation valve to travel
at maximum speed from fully close to fully open. This value must be
set according to the specifications of the valve.
Figure 10: Rotation speed
1
2 3
4 5
6 7
8 9
10 11
12
6
rot
spd
seC
Display stable
This will determine allowed tolerance percentage on the displayed
dose rate. If the difference between the real and the target dose
rates is smaller than it, the target will be displayed.
Figure 11: Display stable
1
2 3
4 5
6 7
8 9
10 11
12
5
dsp
stbl
Total area
This counter is a hidden counter that can be reset only by the
manufacturer. It shows the total area covered since last reset.
Figure 12: Total area
Ha
1
2 3
4 5
6 7
8 9
10 11
12
tot
2134
1
Maximum speed
This counter is a hidden counter that can be reset only by the
manufacturer. It shows the maximum speed reached by the sprayer.
Figure 13: Maximum speed
Km/h
1
2 3
4 5
6 7
8 9
10 11
12
25.2
XI6H