User, Chapter 6 - application setup, Preset flow rate selection – TeeJet 844-AB Sprayer Control User Manual

Page 17: Nozzles per face, Target application rate, Calculation diagnostic

background image

15

98-70007-EN R4

844-AB

CHAPTER 6 - APPLICATION SETUP

Application Setup mode contains the most frequently changed setup

parameters (target application rate and nozzles used). TeeJet has

added this separate setup mode to speed the programming process

when minor changes are made during operation (e.g., changing

orchards, switching nozzles, changing crops, etc.).
To enter Application Setup mode, while in Operations mode press the

Programme key twice (within 3 seconds). One press of the

Programme key will display “PRO USER,” indicating the console

is about to enter Application Setup mode. If the Programme key is

pressed inadvertently, the console will display “PRO USER” for three

seconds before returning to Operations mode. Pressing the

Programme key a second time within 3 seconds will enter

Application Setup mode.
Figure 51: Entering application setup

1

2 3

4 5

6 7

8 9

10 11

12

PRO

USER

Table 4: Application setup mode sequence

Preset flow rate selection
Nozzles per face
Target application rate

Calculation diagnostic

Adjust pressure
Adjust speed

Liquid density

Preset flow rate selection

The symbol will flash at the bottom of the screen. The numbers

1-12, also located at the bottom of the screen, represent the 12

preset dose rates. Use the Plus and Minus keys to toggle

through the presets and select the appropriate one for application.

Press the Programme key to advance to the next step.
Figure 52: Preset flow rate selection

1

2 3

4 5

6 7

8 9

10 11

12

4.1

Bar

8.7

4

90.0

L/Ha

Km/H

Nozzles per face

NOTE: If AB mode has been selected, this step will be skipped and

the screen will advance to Target application rate step.

The nozzle symbol will flash during the Nozzle per Face step. Press

the Plus or Minus keys to adjust the value. Pressing the

Plus or Minus keys simultaneously will clear the value to “0”.

Press the Programme key to advance to the next step.
Figure 53: Nozzles per face

Bar

L/Ha

Km/H

90.0

1

2 3

4 5

6 7

8 9

10 11

12

4

6.9

6.8

Target application rate

The application rate units (e.g., L/Ha) will flash during the Target

application rate step. Press the Plus or Minus keys to adjust

the value of the target application rate. Pressing the Plus and

Minus keys simultaneously will clear the value to “0”. Press the

Programme key to advance to the next step.
Figure 54: Target application rate

1

2 3

4 5

6 7

8 9

10 11

12

6.8

Bar

6.9

4

90.0

L/Ha

Km/H

Calculation diagnostic

NOTE: This step is used for diagnostic purposes only. It has no

affect on the operation of the 844-AB.

This diagnostic tool will allow the operator to adjust the indicated

pressure to see what affect, if any, it would have on operating speed.

The operator can also adjust the speed to see what pressure is

required to maintain the target application rate. This process will

help determine if the correct nozzle configuration was chosen for

the application. While in the calculation step, either the pressure or

speed units will flash.