Application Setup mode contains the most frequently changed setup
parameters (target application rate and nozzles used). TeeJet has
added this separate setup mode to speed the programming process
when minor changes are made during operation (e.g., changing
orchards, switching nozzles, changing crops, etc.).
To enter Application Setup mode, while in Operations mode press the
Programme key twice (within 3 seconds). One press of the
Programme key will display “PRO USER,” indicating the console
is about to enter Application Setup mode. If the Programme key is
pressed inadvertently, the console will display “PRO USER” for three
seconds before returning to Operations mode. Pressing the
Programme key a second time within 3 seconds will enter
Application Setup mode.
Figure 51: Entering application setup
1
2 3
4 5
6 7
8 9
10 11
12
PRO
USER
Table 4: Application setup mode sequence
Preset flow rate selection
Nozzles per face
Target application rate
Calculation diagnostic
Adjust pressure
Adjust speed
Liquid density
Preset flow rate selection
The symbol will flash at the bottom of the screen. The numbers
1-12, also located at the bottom of the screen, represent the 12
preset dose rates. Use the Plus and Minus keys to toggle
through the presets and select the appropriate one for application.
Press the Programme key to advance to the next step.
Figure 52: Preset flow rate selection
1
2 3
4 5
6 7
8 9
10 11
12
4.1
Bar
8.7
4
90.0
L/Ha
Km/H
Nozzles per face
NOTE: If AB mode has been selected, this step will be skipped and
the screen will advance to Target application rate step.
The nozzle symbol will flash during the Nozzle per Face step. Press
the Plus or Minus keys to adjust the value. Pressing the
Plus or Minus keys simultaneously will clear the value to “0”.
Press the Programme key to advance to the next step.
Figure 53: Nozzles per face
Bar
L/Ha
Km/H
90.0
1
2 3
4 5
6 7
8 9
10 11
12
4
6.9
6.8
Target application rate
The application rate units (e.g., L/Ha) will flash during the Target
application rate step. Press the Plus or Minus keys to adjust
the value of the target application rate. Pressing the Plus and
Minus keys simultaneously will clear the value to “0”. Press the
Programme key to advance to the next step.
Figure 54: Target application rate
1
2 3
4 5
6 7
8 9
10 11
12
6.8
Bar
6.9
4
90.0
L/Ha
Km/H
Calculation diagnostic
NOTE: This step is used for diagnostic purposes only. It has no
affect on the operation of the 844-AB.
This diagnostic tool will allow the operator to adjust the indicated
pressure to see what affect, if any, it would have on operating speed.
The operator can also adjust the speed to see what pressure is
required to maintain the target application rate. This process will
help determine if the correct nozzle configuration was chosen for
the application. While in the calculation step, either the pressure or
speed units will flash.