beautypg.com

Up 32, Chapter 8 - features, Boost mode – TeeJet 844-AB Sprayer Control User Manual

Page 20: Area/volume display, Application alarm

background image

18

www.teejet.com

844-AB

CHAPTER 8 - FEATURES

Boost mode

Increased or decreased chemical application may be required during

certain areas of application. The Plus and Minus keys allow for

easy adjustment. Boost mode can be activated while spraying during

“Auto” mode by pressing either the Plus or Minus keys once.

With each subsequent press of the Plus key, the application rate

will increase by 10%. With each subsequent press of the Minus

key, the application rate will decrease by 10%.
If the Plus or Minus key is pressed inadvertently during

operation, a delay of three seconds will deactivate Boost mode.

Succeeding presses will change the target rate in 10% increments to

a maximum of +/- 90% of the target rate.
Example: To increase the application rate by 10%, press the

Plus key once to activate Boost mode. Press the

Plus key again to initiate a 10% increase. To decrease

the application rate by 10%, press the Minus key once to

activate Boost mode. Press the Minus key again to initiate

a 10% decrease.

Application rate changes are monitored on the display as they occur.

The console will display “UP 10”, “UP 20”, “DN 20”, “DN 30”, etc. for

approximately three seconds before returning to actual application

rates.
Figure 60: Boost mode

1

2 3

4 5

6 7

8 9

10 11

12

70

UP

32

Bar

Km/H

L/Ha

0.166

Ha

To return the application rate to the original target rate, use the

Plus or Minus keys individually to increase/decrease the

rate in 10% increments, or press the Plus and Minus keys

simultaneously to return to the programmed target application rate.
NOTE: During boost mode, the target symbol will flash at the top

of the console to indicate the sprayer is not operating at the

target application rate.

Area/volume display

The 844-AB records application area and measures the total volume

applied while the Master boom switch is in the “ON” position. The

area counter measures treated hectares and is dependent on

the value programmed for swath width. The volume measured is

dependent on flow meter impulses and is available on flow-based

models only.
The console will alternately display the treated area sprayed and

the total volume applied (litres) since the last time the area counter/

volume measure was cleared.
To clear the area counter/volume measure, press and hold the

Plus and Minus keys simultaneously for three seconds. The

area/volume measure can only be cleared during Operations mode

with the Master boom switch in the “Off” position.
Figure 61: Area/volume display

1

2 3

4 5

6 7

8 9

10 11

12

60.0

3.1

5.6

Bar

Km/H

L/Ha

1.507

Ha

NOTES: The area counter/volume measure works only when the

Master boom switch is in the “On” position.

If a pressure-based controller is being used, the volume

feature will be disabled. The total area will be displayed at

all times.

Application alarm

If the 844-AB detects a continuous discrepancy of 10% or more

between the Target application rate and the Actual application rate,

the application rate units (L/Ha) will flash in the display window. This

will alert the operator to a problem with the plumbing, operation or

programming.
Figure 62: Application alarm

1

2 3

4 5

6 7

8 9

10 11

12

Err

3.1

4.8

Bar

Km/H

L/Ha

.545

Ha