beautypg.com

118 rad, Lo sim 9.7, High sim 9.0 – TeeJet 844-AB Sprayer Control User Manual

Page 12: Simulated ground speed

background image

10

www.teejet.com

844-AB

Automatic calibration

To automatically calibrate the radar speed sensor, mark a distance

of exactly 100 metres. Press the Plus and Minus keys

simultaneously to clear the contents of the display and to activate

auto calibration mode. Once auto calibration mode is activated,

“RAD” will be displayed on the lower left of the screen.
Figure 32: Radar speed sensor automatic calibration

CAL

118

rAd

1

2 3

4 5

6 7

8 9

10 11

12

Drive toward the initial point of the designated 100 metres. At the

starting location, press the Plus key once to begin the calibration

process. Continue driving the course. The 844-AB will count the

impulses as the sprayer moves. The speed at which the vehicle

travels is not important. As the ending point is reached, press

the Plus key again. The console will display the radar speed

calibration number.
NOTES: The radar speed calibration process should take place in a

field-like environment with the sprayer tank at least half full.

It is recommended to repeat the radar speed calibration

process at least twice and use an average of the speed

calibration numbers.

Manual calculation

It is not possible to manually calculate the calibration value of a

radar. However, the value can be entered manually if it is known

from a prior calibration. To manually enter the radar calibration

value, press the Auto/man key to enter Radar mode. Once radar

calibration mode is activated, “RAD” will be displayed on the lower

left of the screen. Use the Plus or Minus keys to adjust the

value. Press the Programme key to save the value and advance

to the next programme step.

Simulated ground speed

Simulated ground speed allows the console and sprayer to be tested

(and actually spray water) without physically moving the sprayer.

This can and should be tested prior to any spraying activity.
The 844-AB has a low and high simulated ground speed. This allows

the operator to switch between the two to simulate a speed change

and ensure the console is regulating properly during the sprayer

checkout.
Figure 33: Simulated ground speed

Km/H

SPD

LO

SIM

9.7

1

2 3

4 5

6 7

8 9

10 11

12

Km/H

SPD

HIgH

SIM

9.0

1

2 3

4 5

6 7

8 9

10 11

12

To enter simulated speeds, determine whether the low or high

simulated speed is displayed on the console. Change from low to

high by pressing the Auto/man key.
Use the Plus or Minus keys to adjust the values. Press the

Auto/man key to switch to the other setting (either low or high)

and adjust the value with the Plus or Minus keys. Once both

values are entered, press the Programme key to advance to the

next step.
The console will display the simulated speed upon exiting System

Setup mode. The simulated speed will remain on the Operation

mode display until the console receives actual speed impulses. While

in Operation mode, with the Master switch in the “On” position, press

the Programme and Minus keys for low simulated speed;

press the Programme and Plus keys for high simulated speed.
NOTES: The simulated speed feature will be deactivated once

the sprayer begins moving and the 844-AB receives actual

speed impulses. If a radar speed sensor is being used,

disconnect the radar connection from the main console. Any

movement can disable the simulated speed test due to the

sensitivity of the speed sensor.

The LOW SIMULATED SPEED will be used during the first

3 seconds after Master is set in the ON position whatever the

real forward speed. This will help starting a new row in the

best conditions.