ISOBUS Job Computer : BoomPilot

®

APPENDIX A - FACTORY SETTINGS & RANGES

SETUP

GPS Setup

Description

Factory Setting

Range/Options

User Setting

Overlapping

100%

0%, 50%, 100%

GPS Alarm

No GPS Data

No GPS Data
No DGPS Data
No GPS Alarms

GPS Input

Internal

Internal
RS232

Machine Setup

Description

Factory Setting

Range/Options

User Setting

Delay Off

0.0

0.0 - 10.0 sec

Delay On

0.0

0.0 - 10.0 sec

Front or Back Mounted Implement

Back

Front
Back

Distance from Boom to Mount Point

0.00

0.00 - 50.00 m

Distance from Antenna to Mount

Point

0.00

0.00 - 200.00 m

OEM

Description

Factory Setting

Range/Options

User Setting

Antenna Machine Mounted

No

Yes
No

Distance from Hitch to Antenna

0.00

0.00 - 500.00 m

USER INTERFACE

Description

Factory Setting

Range/Options

User Setting

Use Perferred VT

Off

Off
On

Show Number on Soft Key

No

No
Yes

BoomPilot ECU Number (FI)

1

1 - 9

APPENDIX B - UNIT SPECIFICATIONS

Dimensions

19.05 x 18.42 x 6.03 cm

Weight

0.644kg

Connector

30 position Cinch pins. A1-K3
30 position Cinch pins. L1-Y3

Environmental

Operating

-40 to +85°C

Humidity

90% non-condensing

Input/Output

ISO 11783 (ISOBUS)

Power Requirement

<9 watts @12 VDC