APPENDIX A - FACTORY SETTINGS & RANGES
SETUP
GPS Setup
Description
Factory Setting
Range/Options
User Setting
Overlapping
100%
0%, 50%, 100%
GPS Alarm
No GPS Data
No GPS Data
No DGPS Data
No GPS Alarms
GPS Input
Internal
Internal
RS232
Machine Setup
Description
Factory Setting
Range/Options
User Setting
Delay Off
0.0
0.0 - 10.0 sec
Delay On
0.0
0.0 - 10.0 sec
Front or Back Mounted Implement
Back
Front
Back
Distance from Boom to Mount Point
0.00
0.00 - 50.00 m
Distance from Antenna to Mount
Point
0.00
0.00 - 200.00 m
OEM
Description
Factory Setting
Range/Options
User Setting
Antenna Machine Mounted
No
Yes
No
Distance from Hitch to Antenna
0.00
0.00 - 500.00 m
USER INTERFACE
Description
Factory Setting
Range/Options
User Setting
Use Perferred VT
Off
Off
On
Show Number on Soft Key
No
No
Yes
BoomPilot ECU Number (FI)
1
1 - 9
APPENDIX B - UNIT SPECIFICATIONS
Dimensions
19.05 x 18.42 x 6.03 cm
Weight
0.644kg
Connector
30 position Cinch pins. A1-K3
30 position Cinch pins. L1-Y3
Environmental
Operating
-40 to +85°C
Humidity
90% non-condensing
Input/Output
ISO 11783 (ISOBUS)
Power Requirement
<9 watts @12 VDC