SUUNTO SPYDER User Manual
Page 34
32
[30 ft]. By pressing the button, the Spyder will
calculate and show the next deeper no-de-
compression limits in 3 m [10 ft] increments
ending at the depth where no-decompression time
is 0 min or at 45 m [150 ft] (Fig 4.10). By pressing
the
button the next shallower depth will be
shown again.
The Planning Mode can be canceled by pressing
the
or the
button.
NOTE: The Planning Mode is disabled if the
Spyder has entered the Error Mode (See section
4.6, Error Conditions).
Higher Altitude or Personal Adjustment Modes
will shorten the no-decompression time limits.
These limits at different Altitude and Personal
Adjustment Mode selections are shown in Table
8.1 and 8.2 in Section 8.1, Operating Prin-
ciples.
The Spyder will also take into account the calcu-
lated residual nitrogen caused by your previous
dives. The no-decompression times given for dif-
ferent depths will therefore be shorter than be-
fore your first dive.
Fig. 4.10 Planning. The no-
decompression time limit at
30.0 m [100 ft] is 14 minutes in
P1/A0 mode.