Malfunction
Cause
Correction
No round chambered
Magazine not properly inserted,
deformed or dirty
Insert magazine all the way until it
engages (see section 5.7.2)
Rifle requires service
Return to SIG SAUER.
Bolt cannot be inserted into the
action
Mainspring is decocked
Cock the bolt (see section 5.6.1)
Rifle requires service
Return to SIG SAUER.
Rifle cannot be locked
Rifle is decocked
Cock the Rifle (see section 5.6.1)
Rifle requires service
Return to SIG SAUER.
Procedure:
1. Remove magazine and unload the Rifle (see section 5.7.1).
2. Open the bolt.
– The round or cartridge case is pulled out of the barrel chamber and ejected.
3. Check that no bullet, round, cartridge case or foreign matter is in the barrel chamber or barrel. If a projectile is lodged
in the bore, strip the Rifle (see section 8) and have the blockage removed with a suitable tool by a qualified gunsmith.
4. Remove round, cartridge case or foreign bodies. Clean, lubricate and assemble the Rifle (see sections 12 and 9).
5. Have the Rifle inspected by an armorer or gunsmith.
14SIG1027_OM-SSG3000-USA_MiniManual_PeaseREV05.indd 61