IMPORTANT!

Never cut or try to shorten the heating cable.

• Ensure that the EFMA surface is flat against the subfloor;
• Avoid walking on the EFMA system. If you must, wear soft rubber soled shoes;
• Always start unrolling EFMA at least 50 mm (2”) from the walls;
• To work around stationary elements, detach a section of heating cable from the mat

and use it to cover a tight space or work around an object;

• It is important not to subject the heating cable to any mechanical strain (stretching,

radius bending under 20 mm [¾”], scoring).

4.4.2 Mat Rippling

• Carefully flatten the mat against the subfloor to ensure it and the heating cable can

be completely embedded in the cement or other binder to be applied in the next

step;

• If the mat ripples, score the center of the rippled section and flatten the edges (Fig.

4.4.2).

Fig. 4.4 2

IMPORTANT!

Never cut or score the heating cable.

Measure the cable’s electrical and insulation resistance and record the

readings on line 2) After installing the heating cable of the

measures’ table.