AC Line Current / Power vs. Voltage
Under-Voltage Lock-Out (UVLO)
Ballast UVLO = 135V/50Hz 170V to recover
24VDC LVS UVLO = 75V/50Hz 85V to recover
TEST
VOLTS
FREQ
AMPS
VA
POWER
PF
1
170
50Hz
12.53
2130
2124
0.997
2
180
50Hz
11.79
2122
2115
0.996
3
200
50Hz
10.56
2110
2100
0.995
4
200
60Hz
10.53
2106
2096
0.995
5
210
60Hz
10.01
2104
2091
0.994
6
220
50Hz
9.56
2103
2088
0.993
7
230
50Hz
9.13
2100
2083
0.992
8
240
50Hz
8.74
2098
2080
0.990
9
240
60Hz
8.74
2098
2078
0.990
10
250
50Hz
8.38
2095
2074
0.989
11
260
50Hz
8.06
2093
2065
0.986
12
270
50Hz
9.09
2455
2059
0.838
13
270
60Hz
9.08
2449
2065
0.841