BEST BOY

®

WASH LUMINAIRE USER MANUAL

23

Comm LED Operation

The Comm LED - located on the upper enclosure connector panel - indicates system control status. This can be used
determine if the luminaire is receiving a control signal. LED indications are as follows:

Figure 2-13: Comm LED

+

Green - The Comm LED will light green if there is incoming communication.

+

Red - The Comm LED will light red if there is no incoming communication.

+

Blinking - The Comm LED will blink (either red or green) if an error is detected.

Bypassing Calibration

If the menu screen is touched (in the center) and held during startup, the luminaire will present a menu that provides
the option to bypass calibration. This feature allows the luminaire to skip the calibration sequence so that it can be
powered up in the case for configuration purposes.

To bypass calibration:

Step

1. Connect power to luminaire.

Step

2. At startup, touch center of menu screen and hold until Bypass

Calibration menu appears.

Step

3. Press

Yes

to bypass calibration. (The menu will automatically

dismiss if no selection is made within 5 seconds.)

Step

4. Proceed with programming of starting address or other

options.

200 -240 VAC

12A Max

50 / 60 Hz

IN

DMX

THRU

ETHERNET

AC IN

COMM

WAKE

Comm LED