Adjusting lamp, Caution, Optional – PRG Best Boy Wash User Manual User Manual
Page 68

60
BEST BOY
®
WASH LUMINAIRE USER MANUAL
Adjusting Lamp
After a new lamp is installed, the lamp must be aligned to optimize the beam. Adjustment controls are located on the
backcap.
Tools:
#2 Phillips screwdriver
optional
: 5/16"-1/2" telescoping gauge (http://www.mcmaster.com/#inside-micrometers/=r6gx02 - item # 2081A6)
WARNING:
Backcap may be HOT during lamp operation.
To adjust lamp:
Step
1. Power up luminaire and allow to warm up for at least ten minutes.
Step
2. Set intensity to 100%.
Step
3. Position beam on a white wall at a distance of 10' to 20'.
Step
4. At backcap, use three adjustment screws to optimize beam (Figure 4-3).
Figure 4-3: Adjusting the Lamp
Note: Be sure to reset Lamp Hours when installing a new lamp.
DO NOT OPERATE WI THOUT
IN PL AC E OR WHEN LE NS IS
COMPLETE LAMP ENCLOSURE
DAMAGED.
RISK OF EXP OSUR E TO EX CESS IVE
ULTRAVIOLET RADIATION
SOURCE DE RAYONNEMENT UV
FOR 5 MINUTES. DISCONNECT FIXTURE BEFORE RELAMPING OR SERVICING.
NE PAS ENLEVER L ’ECR AN DE
PROTECTION
DANGER: INTENSE HEAT. AVOID CONTACT BY PERSONS AND MATERIALS
COUPER L’ALIMENTATION AVANT LE DEPANNAGE
INSTALL LAMP NIPPLE TOWARD REAR OF FIXTURE.
RISK O F FIRE: USE WITH MA X
1500 WATT LAMP. USE ONLY A
HIGH -PRESSURE LAMP OF DOUBLE-ENDED
TYPE HTI 1500W METAL HALIDE.
DANGER: CHALEUR INTENSE. EVITER TOUT CONTACT ET TENIR TOUTE
MATIERE A L’ECART
WARNING: RISK OF POSSIBLE LAMP EXPLOSION. ALLOW HOUSING TO COOL
ATTENTION: UTILISER UNE
LAMPE 1500 WATTS DOU BLE-CLOS
TYPE HTI METAL H ALID E.
LAMP ADJUST
LAMP ADJUST
LAMP ADJUST
LOOSEN FOR
LAMP ACCESS
LOOSEN FOR
LAMP ACCESS
CAUTION