S56

Ring / Cadence B Maximum On Time

n

0 – 255 in 40 ms unit

0

0 ms

S57

Ring / Cadence B Minimum Off Time

n

0 – 255 in 40 ms unit

0

0 ms

S58

Ring / Cadence B Maximum Off Time

n

0 – 255 in 40 ms unit

0

0 ms

S74

Billing Delay Time

n

20 – 254 in 100 ms unit

20

2 seconds

This register sets the duration of billing delay in units of 100 ms.

Caller ID functions

S95

Caller ID configuration

136

CID disabled

Bit 0

Dual Tone Alert Signal expected

Bit 1:2


Number (0-3) of Line Reversal or Ring Pulse Alert Signals expected before
Caller ID.

Bit 3

CID between 1

st

and 2

nd

ring

Bit 4

Caller ID enabled. Applies only to On-Hook/Offline/Type I Caller ID.

Bit 5

0= FSK, 1 = DTMF based signaling for CID

Bit 6

Enables using USR11 to measure DC offset when entering Idle state

Country selection

dependent (S99)

Country selection

dependent (S99)

Country selection

dependent (S99)

Country selection

dependent (S99)