Caller id functions, Ring / cadence b maximum on time, Ring / cadence b minimum off time – Maxim Integrated Teridian V.22 bis Linux Softmodem for 73M1822/73M1922 MicroDAA User Manual
Page 43: Ring / cadence b maximum off time, Billing delay time, Caller id configuration

UG_1x22_043
V.22 bis Linux Softmodem for 73M1x22 MicroDAA User Guide
Rev. 1.5
43
S56
Ring / Cadence B Maximum On Time
n
0 – 255 in 40 ms unit
0
0 ms
S57
Ring / Cadence B Minimum Off Time
n
0 – 255 in 40 ms unit
0
0 ms
S58
Ring / Cadence B Maximum Off Time
n
0 – 255 in 40 ms unit
0
0 ms
S74
Billing Delay Time
n
20 – 254 in 100 ms unit
20
2 seconds
This register sets the duration of billing delay in units of 100 ms.
Caller ID functions
S95
Caller ID configuration
136
CID disabled
Bit 0
Dual Tone Alert Signal expected
Bit 1:2
Number (0-3) of Line Reversal or Ring Pulse Alert Signals expected before
Caller ID.
Bit 3
CID between 1
st
and 2
nd
ring
Bit 4
Caller ID enabled. Applies only to On-Hook/Offline/Type I Caller ID.
Bit 5
0= FSK, 1 = DTMF based signaling for CID
Bit 6
Enables using USR11 to measure DC offset when entering Idle state
Country selection
dependent (S99)
Country selection
dependent (S99)
Country selection
dependent (S99)
Country selection
dependent (S99)