Pulse dial make time, Pulse dial break time, Pulse dial inter-digit time – Maxim Integrated Teridian V.22 bis Linux Softmodem for 73M1822/73M1922 MicroDAA User Manual
Page 27: Pulse map \ cid control \ black listing control

UG_1x22_043
V.22 bis Linux Softmodem for 73M1x22 MicroDAA User Guide
Rev. 1.5
27
S32
Pulse Dial Make Time
n
1 – 211 in ms unit
39
39 ms
S33
Pulse Dial Break Time
N
1 – 211 in ms unit
61
61 ms
S34
Pulse Dial Inter-digit Time
N
1 – 211 in 10 ms unit
75
750 ms
S72
Pulse Map \ CID control \ Black Listing control
64
10 pulses for 0; D pulses for D from 1 to 9; no CID, no blacklisting
Bit 1-0
00
10 pulses for 0; D pulses for D from 1 to 9
01
10 pulses for 0; 10-D pulses for D from 1 to 9
10
D+1 pulses for D from 0 to 9
Bit 2
Set user control on V24 outputs (CTS, RI…) – See Application Notes -
Bit 3
Enables CID wetting pulse through RELAY signal
Bit 4
Japanese Caller ID – Off hook CID processing -
Bit 5
Japanese Caller ID – Marks start the CID preamble -
Bit 6
Reserved
Bit 7
Black Listing option enabled
Sets the relation between the digit D and the digit pulse dialed.
Country selection
dependent (S99)
Country selection
dependent (S99)
Country selection
dependent (S99)
Country selection
dependent (S99)