27

S32

Pulse Dial Make Time

n

1 – 211 in ms unit

39

39 ms


S33

Pulse Dial Break Time

N

1 – 211 in ms unit

61

61 ms


S34

Pulse Dial Inter-digit Time

N

1 – 211 in 10 ms unit

75

750 ms


S72

Pulse Map \ CID control \ Black Listing control

64

10 pulses for 0; D pulses for D from 1 to 9; no CID, no blacklisting

Bit 1-0

00

10 pulses for 0; D pulses for D from 1 to 9

01

10 pulses for 0; 10-D pulses for D from 1 to 9

10

D+1 pulses for D from 0 to 9

Bit 2

Set user control on V24 outputs (CTS, RI…) – See Application Notes -

Bit 3

Enables CID wetting pulse through RELAY signal

Bit 4

Japanese Caller ID – Off hook CID processing -

Bit 5

Japanese Caller ID – Marks start the CID preamble -

Bit 6

Reserved

Bit 7

Black Listing option enabled

Sets the relation between the digit D and the digit pulse dialed.





Country selection

dependent (S99)

Country selection

dependent (S99)

Country selection

dependent (S99)

Country selection