S48

Busy Tone / Cadence B Maximum On Time

n

0 – 255 in 40 ms unit

0

0 ms


S49

Busy Tone / Cadence B Minimum Off Time

n

0 – 255 in 40 ms unit

0

0 ms

S50

Busy Tone / Cadence B Maximum Off Time

n

0 – 255 in 40 ms unit

0

0 ms

S20

Call Progress Selection

17

Imprecise tones detection only.

Busy tone bits 7-4/ Dial tone bits 3-0

Bit 7/3

Bit 6/2

Bit 5/1

Bit 4/0

Function

0

0

0

1

Detect Imprecise tones ONLY.

0

0

1

0

Detect All Precise tones ONLY.

0

1

0

0

Detect Any of the Precise tones.

S88

Imprecise Filter Selection

0

Filter 280-680Hz selected for pre and post dialing

Bits 3-0 Pre dial imprecise filter selection (dial tone)

Bits 7-4 Post dial imprecise filter selection (busy tone)

Value

Frequency range

Country selection

dependent (S99)

Country selection

dependent (S99)

Country selection

dependent (S99)

Country selection

dependent (S99)

Country selection

dependent (S99)