33
S48
Busy Tone / Cadence B Maximum On Time
n
0 – 255 in 40 ms unit
0
0 ms
S49
Busy Tone / Cadence B Minimum Off Time
n
0 – 255 in 40 ms unit
0
0 ms
S50
Busy Tone / Cadence B Maximum Off Time
n
0 – 255 in 40 ms unit
0
0 ms
S20
Call Progress Selection
17
Imprecise tones detection only.
Busy tone bits 7-4/ Dial tone bits 3-0
Bit 7/3
Bit 6/2
Bit 5/1
Bit 4/0
Function
0
0
0
1
Detect Imprecise tones ONLY.
0
0
1
0
Detect All Precise tones ONLY.
0
1
0
0
Detect Any of the Precise tones.
S88
Imprecise Filter Selection
0
Filter 280-680Hz selected for pre and post dialing
Bits 3-0 Pre dial imprecise filter selection (dial tone)
Bits 7-4 Post dial imprecise filter selection (busy tone)
Value
Frequency range
Country selection
dependent (S99)
Country selection
dependent (S99)
Country selection
dependent (S99)
Country selection
dependent (S99)
Country selection
dependent (S99)