For Enter-Exit applications, the RS-485 electrical interface must be connected between the two EX-10 Exciters and the
RXR-10 Receiver (see Figure 11 for a wiring diagram). The total length of the RS485 wiring must be less than 500 feet.
NOTE: The RS485 interface is only required for two-lane operation. Do NOT connect the RS-485 wiring when in single-
lane operation.
6.0.1
System Checkout
The instructions provided in Section 4.0 apply for Enter-Exit operation; however, they need to be performed for each
vehicle travel lane independently. You may consider reducing each Receiver’s sensitivity to minimize interference
between the vehicle travel lanes.
7.0
Wiring Diagrams
7.1
Dual-Lane Exciters to Receiver
This wiring connection applies to systems in Dual-Lane In/Out applications.
Figure 11: Dual-Lane Exciters to Receiver
RXR-10 Receiver PCB
External
Antenna
Connector
Red LED
Green LED
Beeper
Range
Adjust
Channel
Select
ON
Antenna
Ground
1
2
3
4
5
6
7
+12 VDC
Ground
Ground
Ch A Out/D0
Ch A/D1
Ch B Out/D0
Ch B/D1
Reset
A/Rx
B/Tx
NOTE: The RS-485 connection is
not used when using one Exciter
in a single-lane application.
EX-10
Exciter
ENTER
EX-10
Exciter
Exciter
Antenna
Connection
Exciter
Antenna
Connection
Power
Supply
+ 12 VDC
Ground
Power Lines
Red / Black
RS-485 Data Lines
White / Green
Connect Shields to Ground
EXIT
Arming
Device
RED
BLACK
GREEN
WHITE
BROWN
BLUE
NOTE: Short the Brown
and Blue lines if NO
Arming Device is used.