beautypg.com

Time periods – Maxim Integrated DS80C390 User Manual

Page 36

background image

DS80C390

36 of 58

110199

t

AVDV1

0.75 t

MCS

-20

ns

C

ST

= 0

(C

ST

+0.375)

t

MCS

-20

1

C

ST

3

Port 0 Address, Port 4 CE,
Port 5 PCE to Valid Data In

(C

ST

+1.375)

t

MCS

-20

4

C

ST

7

t

AVDV2

0.875 t

MCS

-20

ns

C

ST

= 0

(C

ST

+0.5)

t

MCS

-20

1

C

ST

3

Port 2, 4 Address to Valid
Data In

(C

ST

+1.5)

t

MCS

-20

4

C

ST

7

t

LLWL

0.125 t

MCS

-5

0.125 t

MCS

+5

ns

C

ST

=0

0.25t

MCS

-5

0.25t

MCS

+5

1

C

ST

3

ALE Low to

RD

or

WR

Low

1.25 t

MCS

-10

1.25 t

MCS

+10

4

C

ST

7

t

AVWL1

0.25 t

MCS

-5

ns

C

ST

= 0

0.5t

MCS

-5

1

C

ST

3

Port 0 Address, Port 4 CE,

Port 5 PCE to

RD

or

WR

Low

2.5 t

MCS

-10

4

C

ST

7

t

AVWL2

0.375 t

MCS

-5

ns

C

ST

= 0

0.625t

MCS

-5

1

C

ST

3

Port 2, 4 Address to or

WR

Low

2.625 t

MCS

-10

4

C

ST

7

Data Valid to

WR

Transition

t

QVWX

-5

ns

Data hold after

WR

high

t

WHQX

0.25 t

MCS

-5

ns

C

ST

= 0

0.5t

MCS

-5

1

C

ST

3

1.5 t

MCS

-10

4

C

ST

7

RD

Low to Address Float

t

RLAZ

-(0.125 t

MCS

-5)

ns

0

C

ST

7

t

WHLH

0

10

ns

C

ST

= 0

0.25 t

MCS

-5

0.25 t

MCS

+5

1

C

ST

3

RD

or

WR

High to ALE,

Port 4 CE or Port 5 PCE
High

1.25 t

MCS

-10

1.25 t

MCS

+10

4

C

ST

7

NOTES FOR MOVX CHARACTERISTICS:

1. All parameters apply to both commercial and industrial temperature operation unless otherwise noted.
2. CST is the stretch cycle value as determined by the MD2, MD1, & MD0 bits of the CKCON register.

t

MCS

is a time period determined by the stretch cycle value, shown in the following table.

t

MCS

TIME PERIODS

System Clock Selection

2X

4X/

CD1

CD0

t

MCS

1

0

0

1 t

CLCL

0

0

0

2 t

CLCL

X

1

0

4 t

CLCL

X

1

1

1024 t

CLCL