Crestron TPS-GA-TPI
Isys
®
G-Series Touchpanel Interface
SETUP MENU
Interface Menu
The TPS-GA-TPI communicates with a control system to activate commands or to
display feedback from components within the system. The communication interface
must be correctly configured or communication will not occur. To set
communication parameters select the Interface button located on the SETUP MENU
and display the INTERFACE MENU.
The Cresnet network identity number (Cresnet ID also known as the Net ID) is
displayed on the INTERFACE MENU. Cresnet ID is the two-digit hexadecimal
number. The hexadecimal number can range from 03 to FE and must correspond to
the Net ID set in the SIMPL Windows program of the Cresnet system. Matching IDs
between the TPS-GA-TPI and the SIMPL Windows program is required if data is to
be successfully transferred. Net ID for the TPS-GA-TPI is factory set to 03. No two
devices in the same system can have the same Net ID.
Operations Guide – DOC. 6609A