Exception alarms
You can set up the camera to notify you when irregular events occur and how
you should be notified. These exception alarms include:
• HDD Full: All recording space of NAS is full.
• HDD Error: Errors occurred while files were being written to the storage, no
storage or storage had failed to initialize.
• Network Disconnected: Disconnected network cable.
• IP Address Conflicted: Conflict in IP address setting.
• Illegal Login: Wrong user ID or password used to login to the cameras.
Figure 10: Exception menu
To define exception alarms:
1. In the
Events
folder, click the
Exception
tab to open its window.
2. Under
Exception Type
, select an exception type from the drop-down list.
3. Check the checkbox to select the linkage method.
4. Click
Save
to save changes.
Alarm inputs and outputs
To define the external alarm input:
1. In the
Events
folder, click the
Alarm Input
tab to open its window.
2. Choose the
Alarm Input No.
and the
Alarm Type
. The alarm type can be NO