Two-way voice operation – Interlogix Simon XT Installation Manual User Manual
Page 67

Simon XT Installation Manual
61
To test communication with the central station:
1. Call the central station and tell the operator that you will be testing the
system.
2. Arm the system.
3. Test each of the wireless panic buttons and trip at least one sensor of each
type (fire, intrusion, etc.) to verify that the appropriate alarms are working
correctly.
4. When you finish testing the system, call the central station to verify that the
alarms were received.
Table 31: Sensor/user report codes
Arm or disarm from
Reports as user
Panel or remote handheld touchpad
0
Key fob
1 to 40 (sensor number)
Panel auxiliary panic
41
Panel tamper
42
Panel police panic
43
Panel fire panic
44
Dealer access code
44
Installer access code
45
Master code
46
Access codes 1 to 8
47 to 54
Duress code
55
Two-way voice operation
For the central station operator to initiate an audio session:
1. After the panel has completed reporting the alarm, pick up the CS phone and
press the * button to start the audio session.
2. Press 1 or 0 to speak, 2 for VOX operation, and 3 or 6 to listen.
3. Press 99 to terminate the session.
Note:
Panel voice announcements are silenced during AVM sessions. If the
operator does not terminate the session correctly, panel announcements may not
occur for up to 90 seconds after the operator hangs up.