Interlogix Simon XT Installation Manual User Manual
Page 49

Simon XT Installation Manual
43
Table 16: Reporting menu
Function
Default Description
Opening reports
Off
Determines whether the panel sends opening reports to a central
station whenever the system is disarmed (on), or not (off). The
User number will be reported as zone number. Key fobs learned
into zones 1 to 40 will report as that zone.
Dealer code = 44, Installer code = 45, Master code = 46, User
code 1 = 47, User code 2 = 48, User code 3 = 49, User code 4 =
50, User code 5 = 51, User code 6 = 52, User code 7 = 53, User
code 8 = 54, Duress code = 55
Closing reports
Off
Determines whether the panel sends closing reports to a central
station whenever the system is armed (on), or not (off). The User
number will be reported as the zone number. Key fobs learned
into zones 1 to 40 will report as that zone.
Dealer code = 44, Installer code = 45, Master code = 46, User
code 1 = 47, User code 2 = 48, User code 3 = 49, User code 4 =
50, User code 5 = 51, User code 6 = 52, User code 7 = 53, User
code 8 = 54, Duress code = 55
Force armed
Off
Determines whether the panel sends by force armed report to a
central station if the user bypasses protesting sensors (indirect
bypass) when arming the system (on), or not (off).
AC power failure
Off
Determines whether the panel sends AC power failure reports to a
central station after the programmed time expires. The time can
be set from 005 to 254 minutes.
When the panel is without AC power for 30 seconds, the panel
LEDs turn off.
When the panel is without AC power for the programmed time, an
AC power failure is reported.
The panel reports an AC power restoral when AC power returns to
the panel.
Low CPU battery
On
Determines whether the panel sends a low CPU battery report to
the central station when the panel backup battery voltage drops.
Sen alarm restore
Off
Determines whether the panel reports sensor alarm restoral (on),
or not (off). Setting when restoral is reported:
1. Immediately after sensor is closed or restored after dial
delay
2. After siren timeout expires if sensor is restored
3. When system is disarmed if sensor is restored.
24-hour sensor
tamper
Off
Determines whether the system (armed or disarmed) goes into
and reports an alarm anytime a sensor tamper switch is tripped
(on), or only when the system is armed and a tamper switch of an
armed sensor is tripped (off).