Interlogix Simon XT Installation Manual User Manual
Page 15

Simon XT Installation Manual
9
T
y
p
e
Name/application
Siren type
D
e
la
y
R
e
s
to
ra
l
S
u
p
e
rv
is
e
d
Active in
arming
levels
10 Entry/exit delay: A delay that requires a standard
delay time. Chime.
Intrusion
S Y Y
24
13 Instant perimeter: Exterior doors and windows.
Chime.
Intrusion
I
Y Y
24
14 Instant interior: Interior door.
Intrusion
F
Y Y
234
15 Instant interior: Interior PIR motion sensor.
Intrusion
F
Y Y
234
16 Instant interior: Interior door.
Intrusion
F
Y Y
34
17 Instant interior: PIR motion sensor and sound
sensor.
Intrusion
F
N Y
34
18 Instant interior: Cross-zone PIR motion sensor.
Intrusion
F
N Y
34
19 Delayed interior: Interior doors that initiate a delay
before going into alarm.
Intrusion
S Y Y
34
20 Delayed interior: PIR motion sensor that initiates a
delay before going into alarm.
Intrusion
S N Y
34
21 Local instant interior: 24-hour local alarm zone
protecting anything that opens and closes. No report.
Intrusion
I
Y Y
1234
22 Local delayed interior: Same as group 21, plus
activation initiates a delay before going into alarm.
No report.
Intrusion
S Y Y
1234
23 Local instant auxiliary: 24-hour local alarm zone
protecting anything that opens and closes. No report.
Emergency
I
Y Y
01234
24 Local instant auxiliary: 24-hour local alarm zone
protecting anything that opens and closes. Sirens
shut off at restoral. No report.
Emergency
I
Y Y
01234
25 Local special chime: Notify the user when a door is
opened.
Three
beeps
I
N Y
01234
26 Fire: 24-hour fire, rate-of-rise heat, and smoke
sensor.
Fire
I
Y Y
01234
27 Lamp control or other customer feature. No report.
Silent
I
Y Y
012345
28 PIR motion sensor, sound sensor, or pressure mat.
RF thermostat. No report
Silent
I
N Y
01234
29 Auxiliary: Freeze sensor.
Trouble
beeps
I
Y Y
01234
32 PIR motion sensor or sound sensor. No report.
Silent
I
N N
01234
34 Carbon monoxide alarm.
Emergency
I
Y Y
01234
35 Entry/exit delay interior PIR motion
Intrusion
S N Y
234