System tests – Interlogix Simon XT Installation Manual User Manual
Page 60

54
Simon XT Installation Manual
Function
Default
Description
Light schedules
Light
schedule,
1 through 8
Off
In this menu, a light schedule can be
programmed for each X-10 module with unit
number from 1 to 8.
Housecode
A
Lock interval
(Light) lock
interval
Blank
This option sets the daily lockout time during
which sensor trips do not activate associated X-
10 lights
System tests
Table 25: System Tests menu
Function
Default
Description
Comm test
The communication test is used to check the phone
communication between the panel and the central station or
voice report destination.
Sensor test
The sensor test is used to check proper sensor operation.
System download
This feature initiates a phone call from the panel to the
Enterprise Downloader.
Resetting memory to factory defaults
To reset the panel to factory defaults:
1. Open the panel cover.
2. Unplug the transformer and disconnect the battery.
3. Press and hold the four arming/status buttons (Doors+Windows, Motions,
Disarm, and Status) on the front of the panel and the tamper switch on the
inside of the panel.
4. Restore power to the panel with the battery while holding the four buttons and
tamper switch.
5. Release the buttons.
6. Plug in the transformer to the outlet.
Note:
The procedure to reset memory to factory defaults is meant to be difficult.
It is also possible to restore power to the panel by plugging in the transformer
first, which allows the panel to be closed so that the tamper switch does not need
to be pressed. If you do this, be sure to reconnect the battery.