Galaxy Audio DS-EQ230 User Manual
Page 8

From the “System Utilities Sub-menu”, pushing “ENTER” and then using the “NAV/PM1” encoder
for scrolling will give access to the following pages:
- Power-On Procedure: this gives you the ability to select the option that will apply when
the DS-EQ230 powers up after being switched on:
By pressing ENTER and rotating the “PM2” or “PM3” encoder, it is possible to choose between
two options: “Fade In On” or “Fade In Off".
The currently running option will be displayed with an asterisk to the right of the option description.
To change the option simply ENTER on the option not displaying the asterisk and that option
Will become active and an asterisk will now appear to the right of the option description.
SYSTEM UTILITY
- Power-On Procedure -
The following two options are available:
FADE-In = Off ... when the DS-EQ230 is turned on, all Outputs regardless of their status before
The Unit was switched off, will be MUTED or UNMUTED automatically. Meaning the DS-EQ230
will have no active Outputs or active Outputs, during the start-up process, depending from the
Outputs’ previous status.
FADE-In = On ... when the DS-EQ230 is turned on, all Outputs not previously muted before the
Unit was switched off will be active. Meaning the DS-EQ230 outputs will be controlled by a volume
ramp to avoid any sudden sound.
If the option “Fade-In=On” is selected, the screen will show the following:
Delay Time/Distance: this page allows you to select the measurement unit to be used for the
Delays: Time (in milliseconds “ms”) or Distance (in meters “m”):
By pressing ENTER and rotating the “PM2” or “PM3” encoder, it is possible to select the
measurement unit to be used for the delay, which will be confirmed by pushing the ENTER button.
The following screen shows the selected delay measurement is Time (milliseconds):
Power-On Procedure
Fade-In: On
SYSTEM UTILITY
- Delay Units -
DPA-240A
1x2 WAY X-OVER
*
Delay Units
Unit : Time (ms)
*
7