SPECIFICATIONS
9.1.
Environmental And Electrical Considerations
AMBIENT TEMPERATURE Storage - 10
o
C to + 70
o
C. Operating - 10
o
C to + 40
o
C
No direct sunlight to fall on the equipment.
HUMIDITY
40% to 90% RH (non condensing)
AIR
The surrounding air should be dust free and not contain any
corrosive gases or materials which could adversely affect the
equipment.
VIBRATION
Severe vibration can affect the accuracy of weighing and damage
electric / electronic components.
PROTECTION
IP 40 for front panel.
ELECTROMAGNETIC /
Heavy electrical equipment should not be installed close to
FIELDS
the weighing equipment.
POWER SUPPLY
7.5 - 10 VAC 50 Hz or 6 – 12 VDC. Consumption 1,8 Wmax.
INCOMING AND/
Relays and contactors connected to the equipment must have
OUTGOING SIGNALS
reliable and effective interference suppression.
Cabling must be performed according to normal practice.
NOTES
WELDING on or in the vicinity of weighing equipment is prohibited.
STATIC loads, caused by thunderstorms, must be prevented
from developing by use of reliable lightning conductors.
ENSURE that the cooling of the equipment is not obstructed.
9.2. Technical
Specifications
DIGITAL PART
VERSION A
MCU 89C55, 20K ROM, 64W serial EEPROM.
VERSION B MCU 89C55, 20K ROM, 64W serial EEPROM, 32K
serial FLASH, battery backed real time clock and totalising
RAM.
SELF DIAGNOSTICS
Hardware and Software, MCU watchdog.
Memory failure.I/O failure.Program check.
COMMUNICATIONS
Serial port RS232C FULL DUPLEX.(1200 baud) (Version B)
Serial port RS485A HALF DUPLEX. (2400-115.000 baud).
DISPLAY
6 digit LED plus annunciators for NET, NO MOTION,
TARE, SP1, SP2. Colour red. Height 14 mm.
KEYBOARD
6
key
membrane
type.
ALIBI MEMORY
Capacity 10.000 records. Cyclic overflow (FIFO).
Display
an
operations.
Checksum
for
each
record.
EMC COMPATIBILITY
Meets or Exceeds EN 45 501 requirements.
DIMENSIONS /
PANEL
144 (L) x 72 (H) x 70 (D) / 450 gr.
WEIGHT
INOX
180 (L) x 108 (H) x 60 (D) / 1,2 kg.
9.3
MAINTENANCE
The unit does not require any routine maintenance. It may be necessary to perform periodic checks
of the calibration of the scale due to mechanical reasons. The frequency of the calibration checks
depends on the application condition and on the required measuring accuracy.
It may happen that, in exceptional conditions, the unit locks on a wrong memory location and it is not
possible to restart because the keyboard is not operative.
To restart it is necessary to switch the power OFF then ON again.
9.4. SERVICE
There are no serviceable parts. The unit may be repaired by trained personnel only.
The user may check cable connection(s) and power supply.