9.

SPECIFICATIONS

9.1.

Environmental And Electrical Considerations

AMBIENT TEMPERATURE Storage - 10

o

C to + 70

o

C. Operating - 10

o

C to + 40

o

C

No direct sunlight to fall on the equipment.

HUMIDITY

40% to 90% RH (non condensing)

AIR

The surrounding air should be dust free and not contain any
corrosive gases or materials which could adversely affect the
equipment.

VIBRATION

Severe vibration can affect the accuracy of weighing and damage
electric / electronic components.

PROTECTION

IP 40 for front panel.

ELECTROMAGNETIC /

Heavy electrical equipment should not be installed close to

FIELDS

the weighing equipment.

POWER SUPPLY

7.5 - 10 VAC 50 Hz or 6 – 12 VDC. Consumption 1,8 Wmax.

INCOMING AND/

Relays and contactors connected to the equipment must have

OUTGOING SIGNALS

reliable and effective interference suppression.
Cabling must be performed according to normal practice.

NOTES

WELDING on or in the vicinity of weighing equipment is prohibited.
STATIC loads, caused by thunderstorms, must be prevented
from developing by use of reliable lightning conductors.
ENSURE that the cooling of the equipment is not obstructed.

9.2. Technical

Specifications

DIGITAL PART

VERSION A

MCU 89C55, 20K ROM, 64W serial EEPROM.

VERSION B MCU 89C55, 20K ROM, 64W serial EEPROM, 32K

serial FLASH, battery backed real time clock and totalising
RAM.

SELF DIAGNOSTICS

Hardware and Software, MCU watchdog.
Memory failure.I/O failure.Program check.

COMMUNICATIONS

Serial port RS232C FULL DUPLEX.(1200 baud) (Version B)
Serial port RS485A HALF DUPLEX. (2400-115.000 baud).

DISPLAY

6 digit LED plus annunciators for NET, NO MOTION,
TARE, SP1, SP2. Colour red. Height 14 mm.

KEYBOARD

6

key

membrane

type.

ALIBI MEMORY

Capacity 10.000 records. Cyclic overflow (FIFO).

Display

an

print

operations.

Checksum

for

each

record.

EMC COMPATIBILITY

Meets or Exceeds EN 45 501 requirements.

DIMENSIONS /

PANEL

144 (L) x 72 (H) x 70 (D) / 450 gr.

WEIGHT

INOX

180 (L) x 108 (H) x 60 (D) / 1,2 kg.


9.3

MAINTENANCE

The unit does not require any routine maintenance. It may be necessary to perform periodic checks
of the calibration of the scale due to mechanical reasons. The frequency of the calibration checks
depends on the application condition and on the required measuring accuracy.
It may happen that, in exceptional conditions, the unit locks on a wrong memory location and it is not
possible to restart because the keyboard is not operative.
To restart it is necessary to switch the power OFF then ON again.


9.4. SERVICE

There are no serviceable parts. The unit may be repaired by trained personnel only.
The user may check cable connection(s) and power supply.

This manual is related to the following products: