beautypg.com

Flintec – Flintec FDT-B User Manual

Page 22

background image

FLINTEC

Document

Date

Code

Rev.

Page

FDT – VERSION A/B – TECH. -REFERENCE MANUAL

05.04.99

FDT.RM

2

22

of 23

P .

PRINT

The scale weight is printed in the internal electronic tally roll.
The command returns the weight and sequence number of the Alibi memory.
Master transmission:

STX ADD P BCS2 BCS1 ETX

FDT response:

STX ADD P yyyyyy

xxxx BCS2 BCS1 ETX

If printing was succesful where xxxx = 4 digit serial number and

yyyyyy: 6 digits weight including decimal point or ------ (empty) or ****** (corrupted data).

or FDT response:

STX ADD NACK

BCS2 BCS1 ETX

If print conditions were not met (Motion, -ve weight etc).


R .

REPRINT

Returns the last weight and sequence number stored in the Alibi memory.
Master transmission:

STX ADD R BCS2 BCS1 ETX

FDT response:

STX ADD R yyyyyy

xxxx BCS2 BCS1 ETX

yyyyyy: 6 digits weight including decimal point or ------ (empty) or ****** (corrupted data).

xxxx: 4 digits serial number.


S .

SELECT FAD

Selects one of the scales in a multi scale network.
Master transmission: XX= FAD address

STX

ADD

S XX

BCS2

BCS1

ETX

FDT response:

STX ADD ACK

BCS2 BCS1 ETX

Err 30 will be displayed if the FAD address is not programmed for polling by the FDT (set up 3).



T. TARE/GROSS
Tares the weight on the scale and switches the FAD-4 to net weight mode.
Master transmission:

STX ADD T BCS2 BCS1 ETX

FDT response: NONE.
Execution of the command should be checked by examining the next status string.


Z .

ZERO SCALE

Sets the scale to zero, if the weight is stable and within 2% of scale capacity .
Master transmission:

STX ADD Z BCS2 BCS1 ETX

FDT response: NONE.
Execution of the command should be checked by examining the next status string.