Flintec – Flintec FDT-B User Manual
Page 22
FLINTEC
Document
Date
Code
Rev.
Page
FDT – VERSION A/B – TECH. -REFERENCE MANUAL
05.04.99
FDT.RM
2
22
of 23
P .
The scale weight is printed in the internal electronic tally roll.
The command returns the weight and sequence number of the Alibi memory.
Master transmission:
STX ADD P BCS2 BCS1 ETX
FDT response:
STX ADD P yyyyyy
xxxx BCS2 BCS1 ETX
If printing was succesful where xxxx = 4 digit serial number and
yyyyyy: 6 digits weight including decimal point or ------ (empty) or ****** (corrupted data).
or FDT response:
STX ADD NACK
BCS2 BCS1 ETX
If print conditions were not met (Motion, -ve weight etc).
R .
REPRINT
Returns the last weight and sequence number stored in the Alibi memory.
Master transmission:
STX ADD R BCS2 BCS1 ETX
FDT response:
STX ADD R yyyyyy
xxxx BCS2 BCS1 ETX
yyyyyy: 6 digits weight including decimal point or ------ (empty) or ****** (corrupted data).
xxxx: 4 digits serial number.
S .
SELECT FAD
Selects one of the scales in a multi scale network.
Master transmission: XX= FAD address
STX
ADD
S XX
BCS2
BCS1
ETX
FDT response:
STX ADD ACK
BCS2 BCS1 ETX
Err 30 will be displayed if the FAD address is not programmed for polling by the FDT (set up 3).
T. TARE/GROSS
Tares the weight on the scale and switches the FAD-4 to net weight mode.
Master transmission:
STX ADD T BCS2 BCS1 ETX
FDT response: NONE.
Execution of the command should be checked by examining the next status string.
Z .
ZERO SCALE
Sets the scale to zero, if the weight is stable and within 2% of scale capacity .
Master transmission:
STX ADD Z BCS2 BCS1 ETX
FDT response: NONE.
Execution of the command should be checked by examining the next status string.