beautypg.com

Flintec – Flintec FDT-B User Manual

Page 21

background image

FLINTEC

Document

Date

Code

Rev.

Page

FDT – VERSION A/B – TECH. -REFERENCE MANUAL

05.04.99

FDT.RM

2

21

of 23

B .

SCALE B

Select scale B in a multi scale network.
Master transmission:

STX ADD B BCS2 BCS1 ETX


FDT response:

STX ADD ACK

BCS2 BCS1 ETX



C .

SCALE A+B

The sum of the weights on scales A and B is returned.
Master transmission:

STX ADD C BCS2 BCS1 ETX


FDT response:

STX ADD ACK

BCS2 BCS1 ETX




F .

FORMAT CUSTOM DOWNLOAD

The commands is used to download custom print formats to FDT.

Master transmission: where 1=format1

STX

ADD

F

1

BCS2

BCS1

ETX


FDT response:

STX ADD ACK

BCS2 BCS1 ETX

To indicate that it is ready to receive a continuous string.

When ACK block from the FDT is received the master should start transmittion of the string.

The FDT remains in the receive mode until P is pressed on the keyboard.

No characters exceeding the full length (512b)will be received.

?

UPLOAD WEIGHT

Returns the current displayed weight plus status or with a message if bit0 of status byte is ‘1’.
In the normal state the FDT will respond within 3-4 character times.
(e.g. With 9600baud, the character time

1 msec, the master should expect reception of STX

from the FDT within 5 msec after the ETX was transmitted from the master).
Master transmission

STX

ADD

? BCS2 BCS1

ETX


FDT response

STX

ADD

?

STATUS BYTE

x x x x x x

BCS2

BCS1

ETX

where ? is replaced in scale A,B mode. 1=scale A, 2=scale B, 0=A+B
and xxxxxx = Weight if bo of status byte is zero , or Message if bo of status byte is one.

STATUS BYTE

b7 b6

b5

B4

b3

b2

b1 b0

Zero or
Parity

1

Sign of weight
0=+ 1=-

No Motion
0=NO,
1=YES

Out of range
0=NO
1=YES

Autozero
0=NO
1=YES

0=Gross
1=Net

0=Normal Weight
1=No Weight Display

This manual is related to the following products: