beautypg.com

Flintec – Flintec FDT-B User Manual

Page 10

background image

FLINTEC

Document

Date

Code

Rev.

Page

FDT – VERSION A/B – TECH. -REFERENCE MANUAL

05.04.99

FDT.RM

2

10

of 23

SETUP 2

(SERIAL PORT 2 / PRINT PARAMETERS)


2.t

PRINT TYPE :

00

PORT DISABLED.

01

TICKET PRINTOUT (Date, time, Nr, weight).

02

CONTINUOUS TRANSMISSION OF WEIGHT.

05

TICKET GROSS, TARE, NET, (quadruple size).

06

SINGLE LINE NUMBER AND GROSS, TARE, NET.

09

HOST COMPUTER MODE.

20

CUSTOM PRINTS . Format 1 in Gross (Max 512 b).

Format 2 in Net (Max 512 b).

2.d

DATA BITS SERIAL CHANNEL 1

17 = 7 data bits / even parity

08

=

8

data

bits

/

no

parity

2.E

ADDRESS OF FDT–52 (A-Z)

2.L

PAGE

LENGTH Ticket

length

in

linefeeds

2.r

PAPER REVERSE

Number of reverse linefeeds before printout

2.A

LEFT MARGIN

Number of spaces from left margin

2.F

PAGE HEADER

Number of linefeeds before printout

2.1 RESERVED
2.2 RESERVED
2.3

PRINT BELOW /

0=NO 1=YES

Printing is inhibited if the weight is less than

MIN. CAPACITY

min (20 scale division) and the display show

Lo CAP briefly.

2.4 RESERVED
2.5 RESERVED
2.6

WAIT UNLOAD

0=NO 1=YES

Inhibits further prints until the weight falls

below min.

2.7

PRINTER ERROR /

0=NO 1=YES

Printer error or paper out will display Err 20

CONTROL

and

transmission

will

be

inhibited.

2.8 RESERVED

SETUP 3

(SERIAL PORT 1 & MODE)


3.t

MODE OF OPERATION

01 = Remote display for continuous weight input.

Use I to select

Instruments (LECW_1 protocol ie. P + 12.345 CR)

and P to accept

02 = FAD mode – Master. Polls FAD’s connected and displays

and proceed.

FAD data.

03 = FAD mode – Slave. Displays data from FAD. Polling of
the FAD’s must be done by another Master

(FDT or PC).

04 = Dual FAD mode – Master. SCALE A/B.

3.b

BAUD RATE

24 = 2400 baud

38 = 38400 baud

Use I to select

96 = 9600 baud

57 = 57600 baud

and

P to accept

19 = 19200 baud

11 = 115 kbaud

and

proceed.

3.d

DATA BITS & PARITY

08 = 8 data bits, no parity

Use I to select

17 = 7 data bits, Even parity

and

P to accept

3.n

NR OF POLLED FAD;

Key in the number of connected FAD’s (decimal 01–63)

Polling

always

starts

with

address

A

(41h

or

65d).

3.E

FAD DISPLAY ADDRESS

Use “DIGIT ENTRY” to key in the FAD address to be
displayed (65–127) by the FDT (decimal).

This manual is related to the following products: