Flintec – Flintec FDT-B User Manual
Page 10
FLINTEC
Document
Date
Code
Rev.
Page
FDT – VERSION A/B – TECH. -REFERENCE MANUAL
05.04.99
FDT.RM
2
10
of 23
SETUP 2
(SERIAL PORT 2 / PRINT PARAMETERS)
2.t
PRINT TYPE :
00
PORT DISABLED.
01
TICKET PRINTOUT (Date, time, Nr, weight).
02
CONTINUOUS TRANSMISSION OF WEIGHT.
05
TICKET GROSS, TARE, NET, (quadruple size).
06
SINGLE LINE NUMBER AND GROSS, TARE, NET.
09
HOST COMPUTER MODE.
20
CUSTOM PRINTS . Format 1 in Gross (Max 512 b).
Format 2 in Net (Max 512 b).
2.d
DATA BITS SERIAL CHANNEL 1
17 = 7 data bits / even parity
08
=
8
data
bits
/
no
parity
2.E
ADDRESS OF FDT–52 (A-Z)
2.L
PAGE
LENGTH Ticket
length
in
linefeeds
2.r
PAPER REVERSE
Number of reverse linefeeds before printout
2.A
LEFT MARGIN
Number of spaces from left margin
2.F
PAGE HEADER
Number of linefeeds before printout
2.1 RESERVED
2.2 RESERVED
2.3
PRINT BELOW /
0=NO 1=YES
Printing is inhibited if the weight is less than
MIN. CAPACITY
min (20 scale division) and the display show
Lo CAP briefly.
2.4 RESERVED
2.5 RESERVED
2.6
WAIT UNLOAD
0=NO 1=YES
Inhibits further prints until the weight falls
below min.
2.7
PRINTER ERROR /
0=NO 1=YES
Printer error or paper out will display Err 20
CONTROL
and
transmission
will
be
inhibited.
2.8 RESERVED
SETUP 3
(SERIAL PORT 1 & MODE)
3.t
MODE OF OPERATION
01 = Remote display for continuous weight input.
Use I to select
Instruments (LECW_1 protocol ie. P + 12.345 CR)
and P to accept
02 = FAD mode – Master. Polls FAD’s connected and displays
and proceed.
FAD data.
03 = FAD mode – Slave. Displays data from FAD. Polling of
the FAD’s must be done by another Master
(FDT or PC).
04 = Dual FAD mode – Master. SCALE A/B.
3.b
BAUD RATE
24 = 2400 baud
38 = 38400 baud
Use I to select
96 = 9600 baud
57 = 57600 baud
and
P to accept
19 = 19200 baud
11 = 115 kbaud
and
proceed.
3.d
DATA BITS & PARITY
08 = 8 data bits, no parity
Use I to select
17 = 7 data bits, Even parity
and
P to accept
3.n
NR OF POLLED FAD;
Key in the number of connected FAD’s (decimal 01–63)
Polling
always
starts
with
address
A
(41h
or
65d).
3.E
FAD DISPLAY ADDRESS
Use “DIGIT ENTRY” to key in the FAD address to be
displayed (65–127) by the FDT (decimal).