MECHANICAL AND ELECTRICAL SPECIFICATIONS

Box:

plastic (PPO), white colour, self-extin-

guishing according to UL94 V-0 (power

module).

Dimensions:

42 x 90 x 30 mm (user interface); 105

x 90,5 x 26 mm (power module).

Installation:

with spacers (user interface); with

OMEGA rail (power module).

Ambient temperature: from 0 to +60 °C.

Humidity:

10 ... 90% without condensation.

Connections:

6.3 x 0.5 mm Faston type connectors.

Power supply:

230 Vac 50-60 Hz (standard); others

available on request.

Measurement input:

1, which can be configured for “J” o “K”

type thermocouples.

Digital input:

1, to select the required set of

parameters.

Measurement range:

from -99 to +700 °C (“J” type

thermocouple); from -99 to +999 °C

(“K” type thermocouple).

Control range setting: from 0 to +999 °C.

ELECTRICAL CONNECTIONS

Example of tipical application.

DIMENSIONAL DATA

Mesure en mm.

EVERY CONTROL S.r.l. - Via Mezzaterra 6 - 32036 Sedico - BELLUNO - ITALY

Tel. 0437/852468 (3 linee r.a.) - Fax 0437/83648

Display:

3 digit display; LED for the indication of the

operating status.

Accuracy:

1 °C.

Buzzer for alarm

indication:

included.

Output:

SPST relay, 6 A 250 Vac (K 1).

Serial link for

data transfer:

TTL with EVCOBUS protocol (standard).